Mostra el registre d'ítem simple

dc.contributor.authorBeck, Thomas R.
dc.contributor.authorAntohe, Andrei
dc.contributor.authorCardellini, Francesco
dc.contributor.authorCucos, Alexandra
dc.contributor.authorFialova, Eliska
dc.contributor.authorGrossi, Claudia
dc.contributor.authorHening, Kinga
dc.contributor.authorJensen, Jens
dc.contributor.authorKastratovic, Dejan
dc.contributor.authorKrivosic, Matej
dc.contributor.authorLobner, Patrick
dc.contributor.authorVargas Drechsler, Arturo
dc.contributor.otherUniversitat Politècnica de Catalunya. Unitat Transversal de Gestió de l'Àmbit de l'Enginyeria Industrial de Barcelona
dc.contributor.otherUniversitat Politècnica de Catalunya. Institut de Tècniques Energètiques
dc.date.accessioned2022-01-20T10:04:52Z
dc.date.available2022-01-20T10:04:52Z
dc.date.issued2021-11-19
dc.identifier.citationBeck, T. [et al.]. The metrological traceability, performance and precision of european radon calibration facilities. "International journal of environmental research and public health", 19 Novembre 2021, vol. 18, núm. 22, p. 12150:1-12150:15.
dc.identifier.issn1660-4601
dc.identifier.urihttp://hdl.handle.net/2117/360104
dc.description.abstractAn interlaboratory comparison for European radon calibration facilities was conducted to evaluate the establishment of a harmonized quality level for the activity concentration of radon in air and to demonstrate the performance of the facilities when calibrating measurement instruments for radon. Fifteen calibration facilities from 13 different European countries participated. They represented different levels in the metrological hierarchy: national metrology institutes and designated institutes, national authorities for radiation protection and participants from universities. The interlaboratory comparison was conducted by the German Federal Office for Radiation Protection (BfS) and took place from 2018 to 2020. Participants were requested to measure radon in atmospheres of their own facilities according to their own procedures and requirements for metrological traceability. A measurement device with suitable properties was used to determine the comparison values. The results of the comparison showed that the radon activity concentrations that were determined by European calibration facilities complying with metrological traceability requirements were consistent with each other and had common mean values. The deviations from these values were normally distributed. The range of variation of the common mean value was a measure of the degree of agreement between the participants. For exposures above 1000 Bq/m3, the variation was about 4% for a level of confidence of approximately 95% (k=2). For lower exposure levels, the variation increased to about 6%.
dc.language.isoeng
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectÀrees temàtiques de la UPC::Enginyeria química::Química del medi ambient
dc.subject.lcshMetrology
dc.subject.lcshEnvironmental monitoring
dc.subject.lcshRadon
dc.subject.lcshCalibration
dc.subject.otherRadon
dc.subject.otherInterlaboratory comparison
dc.subject.otherRadon activity concentration
dc.subject.otherCalibration
dc.subject.otherMetrological traceability
dc.titleThe metrological traceability, performance and precision of european radon calibration facilities
dc.typeArticle
dc.subject.lemacRadó
dc.subject.lemacMetrologia
dc.subject.lemacSeguiment ambiental
dc.subject.lemacCalibratge
dc.contributor.groupUniversitat Politècnica de Catalunya. DRM - Dosimetria i Radiofísica Mèdica
dc.identifier.doi10.3390/ijerph182212150
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://www.mdpi.com/1660-4601/18/22/12150/htm
dc.rights.accessOpen Access
local.identifier.drac32255402
dc.description.versionPostprint (published version)
dc.relation.projectidinfo:eu-repo/grantAgreement/EURAMET/2PE/METROradon
local.citation.authorBeck, T.; Antohe, A.; Cardellini, F.; Cucos, A.; Fialova, E.; Grossi, C.; Hening, K.; Jensen, J.; Kastratovic, D.; Krivosic, M.; Lobner, P.; Vargas, A.
local.citation.publicationNameInternational journal of environmental research and public health
local.citation.volume18
local.citation.number22
local.citation.startingPage12150:1
local.citation.endingPage12150:15


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple