Modal behavior of a reduced scale pump-turbine impeller. Part II. Numerical Simulation

Thumbnail
View/Open
model II.pdf (1,719Mb) (Restricted access)   Request copy 

Què és aquest botó?

Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:

  • Disposem del correu electrònic de l'autor
  • El document té una mida inferior a 20 Mb
  • Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Share:
 
 
10.1088/1755-1315/12/1/012117
 
  View Usage Statistics
Cita com:
hdl:2117/9718

Show full item record
Valero Ferrando, Ma. del CarmenMés informacióMés informació
Huang, Xingxing
Egusquiza Estévez, EduardMés informacióMés informació
Farhat, Mohamed
Avellan, François
Document typeConference lecture
Defense date2010
Rights accessRestricted access - publisher's policy
Attribution-NonCommercial-NoDerivs 3.0 Spain
Except where otherwise noted, content on this work is licensed under a Creative Commons license : Attribution-NonCommercial-NoDerivs 3.0 Spain
Abstract
A numerical simulation has been carried out to analyze the modal behavior of a reduced scale pump-turbine impeller. The simulation has been done using FEM method, in air and in water. The same boundary conditions than in the experiment were considered: free body in air and free body submerged in a reservoir of water. A sensitivity analysis to determine the influence of the number of elements was done. The influence of the input parameters was also taken into account. Finally, a mesh with 165000 elements for the impeller in air and of 508676 for the impeller in water was used. The results obtained with the simulation have been compared with the experimental ones (paper 1). Both the natural frequency values and the mode-shapes were compared. The numerical results showed small deviation from experiment in the first modes in modes with low modal density. In some coupled modes been found. With the updated model the mode-shapes have been analyzed. Some modes with high modal density have been found. As indicated in the experiment, the effect of the added mass reduces the natural frequencies and also changes the characteristics of the coupled modes
CitationValero, M. [et al.]. Modal behavior of a reduced scale pump-turbine impeller. Part II. Numerical Simulation. A: IAHR Symposium on Hydraulic Machinery and Systems. "Proceedings 25th IAHR Symposium on Hydraulic Machinery and Systems". Timisoara: 2010, p. 926-934. 
URIhttp://hdl.handle.net/2117/9718
DOI10.1088/1755-1315/12/1/012117
ISBN978-606-554-136-8
Collections
  • Departament de Mecànica de Fluids - Ponències/Comunicacions de congressos [180]
  • FLUIDS - Enginyeria de Fluids - Ponències/Comunicacions de congressos [46]
Share:
 
  View Usage Statistics

Show full item record

FilesDescriptionSizeFormatView
model II.pdfBlocked1,719MbPDFRestricted access

Browse

This CollectionBy Issue DateAuthorsOther contributionsTitlesSubjectsThis repositoryCommunities & CollectionsBy Issue DateAuthorsOther contributionsTitlesSubjects

© UPC Obrir en finestra nova . Servei de Biblioteques, Publicacions i Arxius

info.biblioteques@upc.edu

  • About This Repository
  • Contact Us
  • Send Feedback
  • Privacy Settings
  • Inici de la pàgina