dc.identifier.citationMartinelli, P., Colombo, M., Tratta, M., Trentini, D., Pialarissi Cavalaro, S.H., de la Fuente, A., Aguado, A., Di Prisco, M. Control procedures to check the a-O relationship used to design a SFRC slab. A: RILEM International Symposium on Fibre Reinforced Concrete. "FRC: The Modern Landscape. BEFIB 2016. Proceedings of the 9th RILEM International Symposium on Fibre Reinforced Concrete". Vancouver: 2016, p. 17-26.
dc.identifier.urihttp://hdl.handle.net/2117/94231
dc.description.abstractIn the paper, the reliability of the Model Code approach for evaluating the bearing capacity of a Steel Fiber Reinforced Concrete (SFRC) elevated slab is discussed with reference to the case of a twostories family house recently built in Italy. To the authors’ knowledge, this is the first realization of SFRC elevated slab in Italy. Six standard notched specimens have been cast and tested through a third point bending test set-up. These tests allowed to classify the fiber reinforced material based on post–cracking residual strengths measured for two different crack openings, respectively related to serviceability and ultimate limit states. In conjunction with the SFRC slab casting, four shallow beams (1.5×0.5×0.25 m) having the same thickness of the slab were cast. The shallow beams have been tested in bending to verify the specific bearing capacity of the slab having used for both the slab and the shallow beams the same casting procedure. After the beam tests, coring procedures have been carried out on the shallow beams in order to measure the SFRC tensile behavior. The cored cylinders were tested with two non-standardized indirect tensile methodologies: Double Edge Wedge Splitting (DEWS) and Double Punch (Barcelona) tests.
dc.format.extent10 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó
dc.subject.lcshFiber-reinforced concrete--Testing
dc.subject.otherfiber reinforced concrete (FRC)
dc.subject.otherelevated slab
dc.subject.otherindirect tensile tests
dc.subject.otherBarcelona test
dc.subject.otherDEWS test
dc.titleControl procedures to check the a-O relationship used to design a SFRC slab
dc.typeConference report
dc.subject.lemacConstrucció en formigó armat amb fibres d'acer
dc.contributor.groupUniversitat Politècnica de Catalunya. EC - Enginyeria de la Construcció
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac19100370
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorMartinelli, P.; Colombo, M.; Tratta, M.; Trentini, D.; Pialarissi Cavalaro, S.H.; de la Fuente, A.; Aguado, A.; Di Prisco, M.
local.citation.contributorRILEM International Symposium on Fibre Reinforced Concrete
local.citation.pubplaceVancouver
local.citation.publicationNameFRC: The Modern Landscape. BEFIB 2016. Proceedings of the 9th RILEM International Symposium on Fibre Reinforced Concrete
local.citation.startingPage17
local.citation.endingPage26


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple