Mostra el registre d'ítem simple
Comparison of IUP 16 and Microscopic Hot Table Methods for Shrinkage Temperature Determination
dc.contributor.author | Font Vallès, Joaquim |
dc.contributor.author | Espejo, Jenifer |
dc.contributor.author | Cuadros, Sara |
dc.contributor.author | Reyes, Maria Reyes |
dc.contributor.author | Bacardit Dalmases, Anna |
dc.contributor.author | Buti Papiol, Salvador |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Química |
dc.date.accessioned | 2010-05-13T09:26:11Z |
dc.date.available | 2010-05-13T09:26:11Z |
dc.date.created | 2010-04-15 |
dc.date.issued | 2010-04-15 |
dc.identifier.citation | Font, J. [et al.]. Comparison of IUP 16 and Microscopic Hot Table Methods for Shrinkage Temperature Determination. "Journal of the Society of Leather Technologists and Chemists", 15 Abril 2010, vol. 94, núm. 2, p. 59-64. |
dc.identifier.issn | 0144-0322 |
dc.identifier.uri | http://hdl.handle.net/2117/7197 |
dc.description.abstract | In the leather industry, shrinkage temperature (Ts) is determined by the IUP 16 method. However, only microanalytical techniques like the Microscopic Hot Table (MHT) method are appropriate for the Ts of leather objects of historial value. No more than 0.1-0.4mg of sample is needed for the test. The precision and accuracy of the MHT method were investigated taking the official IUP 16 method as a reference. It was concluded that the Ts determined by both methods are in good agreement. The MHT method is precise and sensitive enough to state that small changes of 1.3ºC detected in Ts are statistically significant. The method was successfully applied to determine the Ts of several artefacts of the Leather Museum of Igualada. |
dc.format.extent | 6 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Enginyeria química |
dc.subject.lcsh | Temperature |
dc.title | Comparison of IUP 16 and Microscopic Hot Table Methods for Shrinkage Temperature Determination |
dc.type | Article |
dc.subject.lemac | Adoberia |
dc.subject.lemac | Temperatura |
dc.contributor.group | Universitat Politècnica de Catalunya. ENGIBIO - Enginyeria i Biotecnologia |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 2512212 |
dc.description.version | Postprint (published version) |
local.citation.author | Font, J.; Espejo, J.; Cuadros, S.; Reyes, M.; Bacardit, A.; Butí, S. |
local.citation.publicationName | Journal of the Society of Leather Technologists and Chemists |
local.citation.volume | 94 |
local.citation.number | 2 |
local.citation.startingPage | 59 |
local.citation.endingPage | 64 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [58]
-
Articles de revista [2.227]