Mostra el registre d'ítem simple

dc.contributor.authorFont Vallès, Joaquim
dc.contributor.authorEspejo, Jenifer
dc.contributor.authorCuadros, Sara
dc.contributor.authorReyes, Maria Reyes
dc.contributor.authorBacardit Dalmases, Anna
dc.contributor.authorButi Papiol, Salvador
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Química
dc.date.accessioned2010-05-13T09:26:11Z
dc.date.available2010-05-13T09:26:11Z
dc.date.created2010-04-15
dc.date.issued2010-04-15
dc.identifier.citationFont, J. [et al.]. Comparison of IUP 16 and Microscopic Hot Table Methods for Shrinkage Temperature Determination. "Journal of the Society of Leather Technologists and Chemists", 15 Abril 2010, vol. 94, núm. 2, p. 59-64.
dc.identifier.issn0144-0322
dc.identifier.urihttp://hdl.handle.net/2117/7197
dc.description.abstractIn the leather industry, shrinkage temperature (Ts) is determined by the IUP 16 method. However, only microanalytical techniques like the Microscopic Hot Table (MHT) method are appropriate for the Ts of leather objects of historial value. No more than 0.1-0.4mg of sample is needed for the test. The precision and accuracy of the MHT method were investigated taking the official IUP 16 method as a reference. It was concluded that the Ts determined by both methods are in good agreement. The MHT method is precise and sensitive enough to state that small changes of 1.3ºC detected in Ts are statistically significant. The method was successfully applied to determine the Ts of several artefacts of the Leather Museum of Igualada.
dc.format.extent6 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria química
dc.subject.lcshTemperature
dc.titleComparison of IUP 16 and Microscopic Hot Table Methods for Shrinkage Temperature Determination
dc.typeArticle
dc.subject.lemacAdoberia
dc.subject.lemacTemperatura
dc.contributor.groupUniversitat Politècnica de Catalunya. ENGIBIO - Enginyeria i Biotecnologia
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac2512212
dc.description.versionPostprint (published version)
local.citation.authorFont, J.; Espejo, J.; Cuadros, S.; Reyes, M.; Bacardit, A.; Butí, S.
local.citation.publicationNameJournal of the Society of Leather Technologists and Chemists
local.citation.volume94
local.citation.number2
local.citation.startingPage59
local.citation.endingPage64


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple