Detection of demagnetization faults in surface-mounted permanent magnet synchronous motors by means of the zero-sequence voltage component
View/Open
06104129.pdf (1,000Mb) (Restricted access)
Request copy
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Cita com:
hdl:2117/16262
Document typeArticle
Defense date2012-03-01
Rights accessRestricted access - publisher's policy
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
This paper develops and analyzes an online methodology to detect demagnetization faults in surface-mounted permanent magnet synchronous motors. The proposed methodology, which takes into account the effect of the inverter that feeds the machine, is based on monitoring the zero-sequence voltage component of the stator phase voltages. The theoretical basis of the proposed method has been established. Attributes of the method presented here include simplicity, very low computational burden, and high sensibility. Since the proposed method requires access to the neutral point of the stator windings, it is especially useful when dealing with fault tolerant systems. A simple expression of the zero-sequence voltage component is deduced, which is proposed as a fault indicator parameter. Both simulation and experimental results presented in this paper show the potential of the proposed method to provide helpful and reliable data to carry out an online diagnosis of demagnetization failures in the rotor permanent magnets.
CitationUrresty, J. [et al.]. Detection of demagnetization faults in surface-mounted permanent magnet synchronous motors by means of the zero-sequence voltage component. "IEEE transactions on energy conversion", 01 Març 2012, vol. 27, núm. 1, p. 42-51.
ISSN0885-8969
Publisher versionhttp://ieeexplore.ieee.org/xpl/freeabs_all.jsp?arnumber=6104129
Files | Description | Size | Format | View |
---|---|---|---|---|
06104129.pdf | 1,000Mb | Restricted access |