Analisys of noise-injection networks for interferometric-radiometer calibration
Visualitza/Obre
Estadístiques de LA Referencia / Recolecta
Inclou dades d'ús des de 2022
Cita com:
hdl:2117/1461
Tipus de documentArticle
Data publicació2000-04-30
EditorIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Condicions d'accésAccés obert
Tots els drets reservats. Aquesta obra està protegida pels drets de propietat intel·lectual i
industrial corresponents. Sense perjudici de les exempcions legals existents, queda prohibida la seva
reproducció, distribució, comunicació pública o transformació sense l'autorització del titular dels drets
Abstract
The spatial resolution of current space-borne Earth observation radiometers is limited by the physical antenna aperture. This is especially critical at L-band, which exhibits high sensitivity to soil moisture and sea surface salinity. Interferometric radiometers (InR's) are currently being studied by several space agencies as a feasible alternative to overcome this problem. However, their calibration is a crucial issue since most techniques inherited from radio astronomy cannot be directly applied. Due to the large number of receiving channels, calibration techniques based on centralized noise injection from a single noise source will require a large and stable distribution network, which is technically very complex and unacceptable from the point-of-view of mass and volume. Procedures based on distributed noise injection from a set of noise sources through smaller distribution networks have been recently proposed by the authors as an alternative to alleviate these technological problems. In this paper, the analysis of these networks, the impact of the noise generated by the network losses on the calibration, and the impact of front-end reradiated noise are analyzed. Finally, the optimum circuit topologies and tolerances to which these networks have to be characterized in order to achieve the required calibration are derived. These configurations are formed by cascading basic 1:2 and 1:3 isolated power splitters. Isolators at receiver inputs have to be included in order to minimize offsets originating from the correlation of reradiation of receiver noise. It has been found that, in order to satisfy the calibration requirements of InR's, the S-parameters of the ensemble noise-injection network plus isolators have to be known to within 0.025-0.050 dB in amplitude and 0.5° in phase, and their physical temperature known to within 0.5°C.
CitacióCorbella, I.; Camps, A. J.; Torres, F.; Bará, J. Analisys of noise-injection networks for interferometric radiometer calibration. IEEE Transactions on microwave theory and techniques, 2000, vol. 48, núm. 4, p. 545-552.
ISSN0018-9480
Fitxers | Descripció | Mida | Format | Visualitza |
---|---|---|---|---|
analysis noise-injection00842026.pdf | 193,5Kb | Visualitza/Obre |