Mostra el registre d'ítem simple

dc.contributor.authorGómez Clapers, Joan
dc.contributor.authorSerra Rocamora, Albert
dc.contributor.authorCasanella Alonso, Ramón
dc.contributor.authorPallàs-Areny, Ramon
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2014-02-12T15:11:27Z
dc.date.created2013
dc.date.issued2013
dc.identifier.citationGomez, J. [et al.]. Uncertainty factors in time-interval measurements in ballistocardiography. A: IMEKO World Congress. "Proceedings 19th IMEKO TC-4, Barcelona, Spain Universitat Politècnica de Catalunya July 18th and 19th, 2013". Barcelona: 2013, p. 395-399.
dc.identifier.isbn978-84-616-5438-3
dc.identifier.urihttp://hdl.handle.net/2117/21545
dc.description.abstractThere is a growing interest on measuring time intervals between the J peak of the ballistocardiogram (BCG) and several features of other cardiovascular signals such as the ECG in order to obtain cardiovascular function markers. Nevertheless, possible uncertainty factors involved in these measurements have not been identified and analyzed, which is a necessary step to advance towards standardization in this reemerging biomedical engineering field. In this paper we analyze the effect of the low-pass cutoff frequency and phase characteristic of filters, noise and power line interference on J-peak time measurement. We conclude that BCG acquisition systems require a minimum low-pass cutoff frequency of 25 Hz but the phase angle of filters at this frequency introduce more than 6 ms delay that increases with increasing filter order. Further, SNR and power line interference levels respectively below about 25 dB and 30 dB, commonly found in data acquisition systems in this area, may lead to uncertainties in the time position of the J peak of tens of milliseconds, which are comparable to measured time interval changes that may have diagnostic interest.
dc.format.extent5 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Ciències de la salut::Medicina
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura
dc.subject.lcshBallistocardiography
dc.titleUncertainty factors in time-interval measurements in ballistocardiography
dc.typeConference report
dc.subject.lemacCor -- Batecs -- Mesurament
dc.subject.lemacBal·listocardiografia
dc.contributor.groupUniversitat Politècnica de Catalunya. GRUP ISI - Grup d'Instrumentació, Sensors i Interfícies
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac13032079
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorGomez, J.; Serra, A.; Casanella, R.; Pallàs-Areny, R.
local.citation.contributorIMEKO World Congress
local.citation.pubplaceBarcelona
local.citation.publicationNameProceedings 19th IMEKO TC-4, Barcelona, Spain Universitat Politècnica de Catalunya July 18th and 19th, 2013
local.citation.startingPage395
local.citation.endingPage399


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple