Mostra el registre d'ítem simple
Harmonic resonance damping in Wind Power Plant
dc.contributor.author | Nisak, Khairul |
dc.contributor.author | Rauma, Kalle |
dc.contributor.author | Luna Alloza, Álvaro |
dc.contributor.author | Candela García, José Ignacio |
dc.contributor.author | Rodríguez Cortés, Pedro |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica |
dc.date.accessioned | 2013-01-11T12:44:16Z |
dc.date.created | 2012 |
dc.date.issued | 2012 |
dc.identifier.citation | Nisak, K. [et al.]. Harmonic resonance damping in Wind Power Plant. A: IEEE Energy Conversion Congress and Exposition. "Proceedings 4th Annual Energy Conversion Congress and Exposition". 2012, p. 2067-2074. |
dc.identifier.isbn | 978-1-4673-0802-1 |
dc.identifier.uri | http://hdl.handle.net/2117/17278 |
dc.description.abstract | Harmonic is one of main concern in Wind Power Plant (WPP) as growing usage of power electronic converter is observed. Besides the injection of harmonic by individual wind turbine (WT) as source of harmonic, its propagation in network and problem of resonance is also an issue. By implementing passive filter for harmonic mitigation, additional resonance peak is observed due to its interaction with system side impedance. This paper explores the solution for harmonic mitigation with capability of damping resonance in WPP. An aggregated model of 400-MW WPP network is analyzed in correlating resonance and amplification. A passive filter and hybrid filter is designed to mitigate harmonic accordingly. It is shown that hybrid filter able to provide damping capability and improve the performance |
dc.format.extent | 8 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Energies::Energia eòlica |
dc.subject | Àrees temàtiques de la UPC::Energies::Energia eòlica::Centrals eòliques |
dc.subject.lcsh | Wind power plants |
dc.title | Harmonic resonance damping in Wind Power Plant |
dc.type | Conference report |
dc.subject.lemac | Energia eòlica -- Instal·lacions |
dc.subject.lemac | Energia eòlica |
dc.contributor.group | Universitat Politècnica de Catalunya. SEER - Sistemes Elèctrics d'Energia Renovable |
dc.identifier.doi | 10.1109/ECCE.2012.6342557 |
dc.relation.publisherversion | http://cataleg.upc.edu/record=b1353259~S1*cat |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 11067979 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Nisak, K.; Rauma, K.; Luna, A.; Candela, J.; Rodriguez, P. |
local.citation.contributor | IEEE Energy Conversion Congress and Exposition |
local.citation.publicationName | Proceedings 4th Annual Energy Conversion Congress and Exposition |
local.citation.startingPage | 2067 |
local.citation.endingPage | 2074 |