|
|
E-prints UPC >
Altres >
Enviament des de DRAC >
Empreu aquest identificador per citar o enllaçar aquest ítem:
http://hdl.handle.net/2117/9096
|
Ítem no disponible en accés obert per política de l'editorial
| Arxiu |
Descripció |
Mida | Format |
| effectphysicalfitnessendurance.pdf | | 197.88 kB | Adobe PDF |  |
|
| Citació: | Pichini, S. [et al.]. Effect of physical fitness and endurance exercise on indirect biomarkers of growth hormone and insulin misuse: immunoassay-based measurement in urine samples. "Journal of pharmaceutical and biomedical analysis", 2010, vol. 53, núm. 4, p. 1003-1010. |
| Títol: | Effect of physical fitness and endurance exercise on indirect biomarkers of growth hormone and insulin misuse: immunoassay-based measurement in urine samples |
| Autor: | Zuccaro, Piergiorgio; Segura, Jordi; Pacifici, Roberta; Pichini, Simona; Ventura, Rosa; Palmi, Ilaria; Di Carlo, Simonetta; Bacosi, Antonella; Langohr, Klaus ; Abellan, Rosario; Pascual, Jose Antonio |
| Data: | 2010 |
| Tipus de document: | Article |
| Resum: | Indirect biomarkers of recombinant human growth hormone (rhGH), insulin-like growth factor-I (IGF-I), insulin-like growth factor-II (IGF-II), insulin-like growth factor binding proteins (IGFBP-2 and IGFBP-3) and insulin (C-peptide) were measured together with urinary parameters of renal damage ( 2-
microglobulin and proteinuria) by immunoassays, in house validated for the purpose, in 61 subjects (36 elite athletes, 18 recreational athletes and 7 sedentary individuals) with different levels of physical fitness and endurance exercise.
Validation parameters were good for the evaluated assays, excluding a high inter-assay imprecision and inaccuracy of 24 and 26% obtained forGHassay. The range of concentrations found in urine samples under
investigation was generally covered by the calibration curves of the studied immunoassays. However, for the samples below or above the calibration curve, opportune dilution or concentration were performed.
Particularly, C-peptide samples had to be diluted 1:5 and 2-microglobulin ones assayed using a triple sample volume, to fall within the calibration range.
Urinary C-peptide was the only biomarker statistically higher in samples of elite athletes when compared to recreational athletes and sedentary individuals.
Among elite athletes, taekwondo athletes showed the highest IGF-II basal values while weightlifting athletes showed the lower IGF-I and IGFBP-3 basal values. The trend observed in weightlifters basal samples was confirmed in their training samples: IGF-I, IGF-II, IGFBP-3 and 2-microglobulin were lower in with respect to those from synchronised swimming.
Over the training season, within athlete variability was observed for IGFBP-3 for weightlifting athletes.
In the studied subjects, no direct associations were found between biomarkers of GH or insulin misuse and urinary parameters of renal damage, eventually due to high-workload endurance training.
The variations observed in different biomarkers should be taken in consideration in the hypothesis of setting reference concentration ranges for doping detection. |
| ISSN: | 0731-7085 |
| URI: | http://hdl.handle.net/2117/9096 |
| Versió de l'editor: | 10.1016/j.jpba.2010.06.032 |
| Apareix a les col·leccions: | Altres. Enviament des de DRAC Departament d'Estadística i Investigació Operativa. Articles de revista GREMA - Grup de Recerca en Estadística Matemàtica i les seves Aplicacions. Articles de revista
|
| Comparteix: |
|
Aquest ítem (excepte textos i imatges no creats per l'autor) està subjecte a una llicència de Creative Commons Llicència Creative Commons
|