Mostra el registre d'ítem simple

dc.contributor.authorGómez Clapers, Joan
dc.contributor.authorSerra Rocamora, Albert
dc.contributor.authorCasanella Alonso, Ramón
dc.contributor.authorPallàs-Areny, Ramon
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2014-10-15T15:16:01Z
dc.date.available2014-10-15T15:16:01Z
dc.date.created2014-09-16
dc.date.issued2014-09-16
dc.identifier.citationGomez-Clapers, J. [et al.]. Towards the standardization of ballistocardiography systems for J-peak timing measurement. "Measurement", 16 Setembre 2014, vol. 58, p. 310-316.
dc.identifier.issn0263-2241
dc.identifier.urihttp://hdl.handle.net/2117/24378
dc.description.abstractThere is a growing interest in accurately measuring the timing of the J peak of the ballistocardiogram (BCG) in order to obtain cardiovascular function markers non-invasively, especially in modern home healthcare applications. In this paper we have studied the effect that some common uncertainty sources have in the time measurement of the J peak. This is a necessary step towards the standardization of modern ballistocardiography systems equivalent to that available for ECG systems. We conclude that, to reduce J peak time uncertainty below the measured intrinsic uncertainty of about ±2 ms, the minimal bandwidth should be from 1.5 Hz to 22.5 Hz; the sampling frequency can be decreased up to 50 Hz when using cubic spline interpolation; 5 bits are required to quantify the signal, and signal-to-noise ratio (SNR) and signal-to-interference ratio (SIR) should be over 40 dB and 3 dB respectively.
dc.format.extent7 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura
dc.subjectÀrees temàtiques de la UPC::Ciències de la salut
dc.subject.lcshBallistocardiography
dc.subject.otherBallistocardiogram
dc.subject.otherAcquisition system
dc.subject.otherBiomedical instrumentation
dc.subject.otherStandardization
dc.titleTowards the standardization of ballistocardiography systems for J-peak timing measurement
dc.typeArticle
dc.subject.lemacCardiologia
dc.subject.lemacSang -- Circulació
dc.subject.lemacPressió sanguínia
dc.subject.lemacHemodinàmica
dc.subject.lemacCor -- Batecs -- Mesurament
dc.contributor.groupUniversitat Politècnica de Catalunya. GRUP ISI - Grup d'Instrumentació, Sensors i Interfícies
dc.identifier.doi10.1016/j.measurement.2014.09.003
dc.relation.publisherversionhttp://www.sciencedirect.com/science/article/pii/S0263224114003820
dc.rights.accessOpen Access
local.identifier.drac15205102
dc.description.versionPostprint (author’s final draft)
local.citation.authorGomez-Clapers, J.; Serra, A.; Casanella, R.; Pallàs-Areny, R.
local.citation.publicationNameMeasurement
local.citation.volume58
local.citation.startingPage310
local.citation.endingPage316


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple