Citació: Hernández, V.; Sempau, J. The influence of the field setup on the dosimetry of abutted fields in single-isocenter half-beam techniques. "Medical physics", Març 2011, vol. 38, núm. 3, p. 1468-1472.
Títol: The influence of the field setup on the dosimetry of abutted fields in single-isocenter half-beam techniques
Autor: Hernández, V.; Sempau Roma, Josep Veure Producció científica UPC
Data: mar-2011
Tipus de document: Article
Resum: Purpose: To study the influence of the field setup on the dosimetry at the junction in singleisocenter half-beam techniques. Methods: The dosimetry at the junction for a two-field setup with the gantry at zero was first evaluated with radiochromic films. A three-field setup, with an anterior field and two opposed lateral fields, was also analyzed for two different relative positions of the fields involved. In all cases, the dose increase at the central axis, called the junction dose, was measured. Results: Junction doses varied greatly with the setup. For the three-field setup, the junction dose differed from that obtained with the two-field setup, and it greatly depended on the relative position of the fields. When the anterior field was closer to the gantry than the lateral fields, a field gap occurred and the junction dose was negative. When the anterior field was farther from the gantry than the lateral fields, a field overlap was obtained and the junction dose was positive. The difference in the junction dose between the three-field setups was around 18% for the three accelerators evaluated. Conclusions: Having a uniform dose distribution for two fields at gantry 0° does not guarantee a uniform distribution at other gantry angles. Junction doses are largely affected by the relative position of the radiation fields, which may have an impact in clinical practice. Therefore, any method aiming to assess or to optimize the dose homogeneity at the junction should take this effect into account.
ISSN: 0094-2405
URI: http://hdl.handle.net/2117/12313
DOI: 10.1118/1.3557882
Apareix a les col·leccions:Altres. Enviament des de DRAC
GREENER - Grup de recerca d´estudis energètics i de les radiacions. Articles de revista
Institut de Tècniques Energètiques. Articles de revista
Comparteix:


Stats Mostra les estadístiques d'aquest ítem

SFX Query

Aquest ítem (excepte textos i imatges no creats per l'autor) està subjecte a una llicència de Creative Commons Llicència Creative Commons
Creative Commons

 

Valid XHTML 1.0! Programari DSpace Copyright © 2002-2004 MIT and Hewlett-Packard Comentaris
Universitat Politècnica de Catalunya. Servei de Biblioteques, Publicacions i Arxius