Mostra el registre d'ítem simple
Compact fluorescent lamp modeling for large-scale harmonic penetration studies
dc.contributor.author | Molina, Julio |
dc.contributor.author | Sainz Sapera, Luis |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica |
dc.date.accessioned | 2017-01-25T08:33:29Z |
dc.date.issued | 2014-10-20 |
dc.identifier.citation | Molina, J., Sainz, L. Compact fluorescent lamp modeling for large-scale harmonic penetration studies. "IEEE transactions on power delivery", 20 Octubre 2014, vol. 30, núm. 3, p. 1523-1531. |
dc.identifier.issn | 0885-8977 |
dc.identifier.uri | http://hdl.handle.net/2117/99987 |
dc.description.abstract | Low-watt compact fluorescent lamps (CFLs) may account for significant energy consumption of power distribution feeders in future years. This can lead to power-quality concerns because these devices consume highly distorted currents. In order to predict CFL harmonic current emissions into networks, CFL models capable of predicting these emissions accurately are being studied. On the other hand, these models require great computational effort in large-scale CFL penetration studies. This paper presents and discusses several approximate CFL models based on the harmonic-coupled admittance matrix model which reduces the computational effort while maintaining reasonable accuracy. The performance of the models is validated with CFL laboratory measurements. |
dc.format.extent | 9 p. |
dc.language.iso | eng |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject | Àrees temàtiques de la UPC::Enginyeria elèctrica |
dc.subject | Àrees temàtiques de la UPC::Enginyeria elèctrica::Maquinària i aparells elèctrics::Làmpades elèctriques |
dc.subject.lcsh | Fluorescent lamps |
dc.subject.lcsh | Electric power consumption |
dc.subject.other | Energy consumption |
dc.subject.other | Fluorescent lamps |
dc.subject.other | Power supply quality |
dc.subject.other | Compact fluorescent lamp modeling |
dc.subject.other | Energy consumption |
dc.subject.other | Harmonic-coupled admittance matrix model |
dc.subject.other | Large-scale harmonic penetration studies |
dc.subject.other | Oower distribution feeders Power-quality |
dc.subject.other | Compact fluorescent lamps (CFLs) |
dc.title | Compact fluorescent lamp modeling for large-scale harmonic penetration studies |
dc.type | Article |
dc.subject.lemac | Làmpades fluorescents |
dc.subject.lemac | Energia elèctrica--Consum |
dc.contributor.group | Universitat Politècnica de Catalunya. QSE - Qualitat del Subministrament Elèctric |
dc.identifier.doi | 10.1109/TPWRD.2014.2363143 |
dc.relation.publisherversion | http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumber=6930806&tag=1 |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 18740967 |
dc.description.version | Postprint (author's final draft) |
dc.date.lift | 10000-01-01 |
local.citation.author | Molina, J.; Sainz, L. |
local.citation.publicationName | IEEE transactions on power delivery |
local.citation.volume | 30 |
local.citation.number | 3 |
local.citation.startingPage | 1523 |
local.citation.endingPage | 1531 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [78]
-
Articles de revista [884]