Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions
Cita com:
hdl:2117/99956
Document typeArticle
Defense date2016-07-01
Rights accessOpen Access
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
Demagnetization fault detection of in-service permanent magnet synchronous machines (PMSMs) is a challenging task, because most PMSMs operate under nonstationary circumstances in industrial applications. A novel approach based on tracking characteristic orders of stator current using Vold-Kalman filter is proposed to detect the partial demagnetization fault in PMSMs running at nonstationary conditions. The amplitude of envelope of the fault characteristic orders is used as fault indictor. Experimental results verify the superiority of the proposed method on the partial demagnetization online fault detection of PMSMs under various speed and load conditions.
CitationWang, C., Delgado Prieto, M., Romeral, L., Chen, Z., Blaabjerg, F., Liu, X. Detection of partial demagnetization fault in PMSMs operating under nonstationary conditions. "IEEE transactions on magnetics", 1 Juliol 2016, vol. 52, núm. 7.
ISSN0018-9464
Publisher versionhttp://ieeexplore.ieee.org/document/7372433/?arnumber=7372433
Files | Description | Size | Format | View |
---|---|---|---|---|
Detection+of+Pa ... nstationary+Conditions.pdf | 352,1Kb | View/Open |