Abstract
This paper is focused on the detailed analysis of a PCM plate heat storage unit with a particular configuration, looking for the maximum contact area with the fluid (water) and the minimum volume to be used in a real household application. In that sense, a numerical study of the thermal and fluid dynamic behaviour of the water flow and the PCM melting-solidification processes, together with the thermal behaviour of the solid elements of the unit, has been carried out. On the other hand, an experimental set-up has been designed and built to validate the numerical model and characterise the performance of the heat storage unit. The purpose of the numerical and experimental study is to present a series of results to describe the heat storage unit performance in function of the time. Thus, after a preliminary design study three different cases have been simulated and tested. A 7.2% of discrepancy between numerical results and experimental data has been evaluated for the heat transfer. The PCM heat storage unit designed is capable to store approx. 75% of the thermal energy from the previous process wasted water heat, and recover part of it to supply around 50% of the thermal energy required to heat up the next process.
Descripció
© 2016. This version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
CitacióMorales-Ruiz, S., Rigola, J., Oliet, C., Oliva, A. Analysis and design of a drain water heat recovery storage unit based on PCM plates. "Applied energy", 1 Octubre 2016, vol. 179, p. 1006-1019.
ISSN0306-2619
Versió de l'editorhttp://www.sciencedirect.com/science/article/pii/S030626191631008X