Model developments for in silico studies of the lumbar spine biomechanics
Cita com:
hdl:2117/93381
Chair / Department / Institute
Universitat Politècnica de Catalunya. Departament de Ciència dels Materials i Enginyeria Metal·lúrgica
Document typeDoctoral thesis
Data de defensa2009-06-22
PublisherUniversitat Politècnica de Catalunya
Rights accessOpen Access
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
La present tesi investiga l'ús de la modelització amb elements finits per a l'estudi de la biomecànica lumbar per a l'avaluació clínica. Els estudis bibliogràfics del capítol 1 mostren relacions funcionals clares entre les forces externes i les estructures i formes del teixit lumbar. Els estudis clínics demostraren que independentment del seu origen, el dolor lumbar pot veure's empitjorat per sobrecàrregues dels teixits. Les mesures experimentals són insuficients per descriure la distribució de càrrega entre els diferents teixits lumbars, és així que s'han utilitzat models d'elements finits. No obstant, la fiabilitat dels models a l'hora de predir les càrregues locals en els teixits no ha estat demostrada, essent aquest un dels objectes d'estudi.
En el Capítol 2 s'elaborà un model bisegment de la columna lumbar. El model inicial es completà incloent el còrtex vertebral, una definició complerta de les juntes sinovials, les plaques terminals de cartílag i una descripció millorada de l'estructura de l'anell. Es van simular càrregues simplificades per als estudis in vitro per calcular les distribucions de tensions, deformacions i energia. El model bisegment és vàlid per interpretar les distribucions de càrrega funcionals a L3-L5 en el cas d'estructures conegudes de teixit, però el conjunt de la geometria L3-L5 necessitava ser millorat.
Així al Capítol 3 es creà un model geomètric bisegment precís de L3-L5. El nou model incloïa les corregides: dimensions i formes, alçades de disc, localitzacions del nucli, formes posteriors de l'os, i distribució dels lligaments. Després de comparar a nivell biomecànic l'antiga geometria amb la nova, els resultats mostraren que els rols relatius dels teixits modelats depenen de la geometria. En general, les distribucions de càrrega predites eren més fisiològiques en el nou model. En canvi, ambdós models, reprodueixen rangs experimentals de moviment, així doncs la seva validació hauria de tenir en compte les transferències de càrrega locals.
El Capítol 4 es centra en la variabilitat dels angles creuats del col·lagen de l'anell. Es crearen quatre models bisegment amb organitzacions d'anell fibrós basats en la bibliografia comparant-se sota diverses càrregues. A més es proposà un paràmetre d'estabilització de l'anell per analogia a un tub de parets gruixudes. La biomecànica del model depenia en gran mesura de l'organització de l'anell fibrós, però el paràmetre d'estabilització era soviet contradictori amb les tensions i forces predites. Així, s'assumí que la geometria de la columna i l'organització de l'anell fibrós estaven lligades. Les xarxes d'anell de col·lagen adaptades es poden determinar numèricament, però els models d'anell haurien d'estar bastats en relacions mecanobiològiques.
Al Capítol 5 es presenta un model de disc artificial acoblat amb el model de L3-L5. Models bisegment amb i sense implant van ser comparats amb càrregues controlades per força o desplaçament, incloent o no l'aproximació del pes del cos. La rigidesa de la pròtesi alterava generalment les distribucions de càrrega i les rotacions controlades per desplaçament conduint a grans efectes adjacents. Incloent el pes del cos les condicions de contorn semblaven més fisòlogiques que sense. Malgrat la rigidesa del nou disc, aquest sembla més prometedor que altres dispositius comercials.
En aquesta tesi s'han creat sis models nous elements finits de la columna lumbar osteoligamentosa. Les simulacions han mostrat que l'ús fiable dels models requereix d'una descripció precisa de les càrregues locals i respostes mecàniques de teixits. Les prediccions locals van estar limitades qualitativament degudes al desconeixement de les estructures de teixit tou, equacions constitutives i condicions de contorn. En canvi, els models poden ser emprats com a laboratoris in silico per superar aquestes limitacions. Basat en la informació numèrica i experimental, s'ha proposat un procediment jeràrquic per al desenvolupament qualitativament fiable de models elements finits de la columna lumbar. This PhD thesis investigated the use of finite element modelling to study lumbar spine biomechanics for clinical assessment. Bibliographic studies reported in the first Chapter showed clear functional relations between external forces and lumbar spine tissue structures and shapes. Clinical research revealed that independently of its origin, low back pain may be worsened by altered tissue mechanical environments. Experimental measurements alone cannot truly describe the load distributions between the different lumbar spine tissues. Thus, finite element models have been used in the past. But model reliability in predicting local tissue loadings is still not manifest and has been explored in this thesis as described in the following chapters.
In Chapter 2, a L3-L5 lumbar spine bi-segment model was built. An initial model was completed to include the vertebral cortex, a full definition of the facet joints, the cartilage endplates, and an improved description of the annulus fibre-reinforced structure. Simplified load-cases used for in vitro studies were simulated to calculate stress and strain energy distributions. Predictions within the L3-L5 lumbar spine bi-segment model could be interpreted in terms of functional load distributions related to known tissue structures, but the overall L3-L5 bisegment model geometry needed further update.
Thus, in Chapter 3, a geometrically accurate L3-L5 lumbar spine bi-segment model was created. The new model included corrected L3 and L5 body shapes and dimensions, corrected disc heights and nucleus placements, corrected posterior bone shapes, dimensions, and orientations, and corrected ligament distributions. The new and old geometries were biomechanically compared. Results showed that the relative roles of modelled tissues greatly depend on the geometry. Predicted load distributions were generally more physiological in the new model. However, new and old models could both reproduce experimental ranges of motion, meaning that their validation should take into account local load transfers.
Chapter 4 focuses on the variability of the annulus collagen criss-cross angles. Four bi-segment models with literature-based annulus fibre organizations were created and compared under diverse loads. Moreover, an annulus stabilization parameter was proposed by analogy to a thick walled pipe. Model biomechanics greatly depended on the annulus fibre organization, but annulus stabilization parameter was often contradictory with the predicted stresses and strains. Spine geometry and annulus fibrous organization were hypothesized to be linked together. Adapted annulus collagen networks may be numerically determined, but annulus modelling should be based on mechano-biological relationships.
In Chapter 5, a case-study of a novel artificial disc design coupled with the L3-L5 lumbar spine model is presented. Bi-segment models with and without implant were compared under load- or displacement-controlled rotations, with or without body-weight like load. Prosthesis stiffness generally altered the load distributions and displacement-controlled rotations led to strong adjacent level effects. Including body weight-like loads seemed to give more realistic results. Although the novel disc substitute is too stiff, it is more promising than other existing commercial devices.
In this thesis, six new osteoligamentous lumbar spine bi-segment finite element models were created. Simulations showed that reliable use of lumbar spine finite element models requires precise descriptions of local tissue loading and response. Local predictions were qualitatively mainly limited by a lack of knowledge about soft tissue structural organisations, constitutive equations, and boundary conditions. However, models can be used as in silico laboratories to overcome such limitations. A hierarchical procedure for the development of qualitatively reliable lumbar spine finite element models was proposed based on available numerical and experimental inputs.
En el Capítol 2 s'elaborà un model bisegment de la columna lumbar. El model inicial es completà incloent el còrtex vertebral, una definició complerta de les juntes sinovials, les plaques terminals de cartílag i una descripció millorada de l'estructura de l'anell. Es van simular càrregues simplificades per als estudis in vitro per calcular les distribucions de tensions, deformacions i energia. El model bisegment és vàlid per interpretar les distribucions de càrrega funcionals a L3-L5 en el cas d'estructures conegudes de teixit, però el conjunt de la geometria L3-L5 necessitava ser millorat.
Així al Capítol 3 es creà un model geomètric bisegment precís de L3-L5. El nou model incloïa les corregides: dimensions i formes, alçades de disc, localitzacions del nucli, formes posteriors de l'os, i distribució dels lligaments. Després de comparar a nivell biomecànic l'antiga geometria amb la nova, els resultats mostraren que els rols relatius dels teixits modelats depenen de la geometria. En general, les distribucions de càrrega predites eren més fisiològiques en el nou model. En canvi, ambdós models, reprodueixen rangs experimentals de moviment, així doncs la seva validació hauria de tenir en compte les transferències de càrrega locals.
El Capítol 4 es centra en la variabilitat dels angles creuats del col·lagen de l'anell. Es crearen quatre models bisegment amb organitzacions d'anell fibrós basats en la bibliografia comparant-se sota diverses càrregues. A més es proposà un paràmetre d'estabilització de l'anell per analogia a un tub de parets gruixudes. La biomecànica del model depenia en gran mesura de l'organització de l'anell fibrós, però el paràmetre d'estabilització era soviet contradictori amb les tensions i forces predites. Així, s'assumí que la geometria de la columna i l'organització de l'anell fibrós estaven lligades. Les xarxes d'anell de col·lagen adaptades es poden determinar numèricament, però els models d'anell haurien d'estar bastats en relacions mecanobiològiques.
Al Capítol 5 es presenta un model de disc artificial acoblat amb el model de L3-L5. Models bisegment amb i sense implant van ser comparats amb càrregues controlades per força o desplaçament, incloent o no l'aproximació del pes del cos. La rigidesa de la pròtesi alterava generalment les distribucions de càrrega i les rotacions controlades per desplaçament conduint a grans efectes adjacents. Incloent el pes del cos les condicions de contorn semblaven més fisòlogiques que sense. Malgrat la rigidesa del nou disc, aquest sembla més prometedor que altres dispositius comercials.
En aquesta tesi s'han creat sis models nous elements finits de la columna lumbar osteoligamentosa. Les simulacions han mostrat que l'ús fiable dels models requereix d'una descripció precisa de les càrregues locals i respostes mecàniques de teixits. Les prediccions locals van estar limitades qualitativament degudes al desconeixement de les estructures de teixit tou, equacions constitutives i condicions de contorn. En canvi, els models poden ser emprats com a laboratoris in silico per superar aquestes limitacions. Basat en la informació numèrica i experimental, s'ha proposat un procediment jeràrquic per al desenvolupament qualitativament fiable de models elements finits de la columna lumbar.
In Chapter 2, a L3-L5 lumbar spine bi-segment model was built. An initial model was completed to include the vertebral cortex, a full definition of the facet joints, the cartilage endplates, and an improved description of the annulus fibre-reinforced structure. Simplified load-cases used for in vitro studies were simulated to calculate stress and strain energy distributions. Predictions within the L3-L5 lumbar spine bi-segment model could be interpreted in terms of functional load distributions related to known tissue structures, but the overall L3-L5 bisegment model geometry needed further update.
Thus, in Chapter 3, a geometrically accurate L3-L5 lumbar spine bi-segment model was created. The new model included corrected L3 and L5 body shapes and dimensions, corrected disc heights and nucleus placements, corrected posterior bone shapes, dimensions, and orientations, and corrected ligament distributions. The new and old geometries were biomechanically compared. Results showed that the relative roles of modelled tissues greatly depend on the geometry. Predicted load distributions were generally more physiological in the new model. However, new and old models could both reproduce experimental ranges of motion, meaning that their validation should take into account local load transfers.
Chapter 4 focuses on the variability of the annulus collagen criss-cross angles. Four bi-segment models with literature-based annulus fibre organizations were created and compared under diverse loads. Moreover, an annulus stabilization parameter was proposed by analogy to a thick walled pipe. Model biomechanics greatly depended on the annulus fibre organization, but annulus stabilization parameter was often contradictory with the predicted stresses and strains. Spine geometry and annulus fibrous organization were hypothesized to be linked together. Adapted annulus collagen networks may be numerically determined, but annulus modelling should be based on mechano-biological relationships.
In Chapter 5, a case-study of a novel artificial disc design coupled with the L3-L5 lumbar spine model is presented. Bi-segment models with and without implant were compared under load- or displacement-controlled rotations, with or without body-weight like load. Prosthesis stiffness generally altered the load distributions and displacement-controlled rotations led to strong adjacent level effects. Including body weight-like loads seemed to give more realistic results. Although the novel disc substitute is too stiff, it is more promising than other existing commercial devices.
In this thesis, six new osteoligamentous lumbar spine bi-segment finite element models were created. Simulations showed that reliable use of lumbar spine finite element models requires precise descriptions of local tissue loading and response. Local predictions were qualitatively mainly limited by a lack of knowledge about soft tissue structural organisations, constitutive equations, and boundary conditions. However, models can be used as in silico laboratories to overcome such limitations. A hierarchical procedure for the development of qualitatively reliable lumbar spine finite element models was proposed based on available numerical and experimental inputs.
Description
Premi extraordinari doctorat curs 2008-2009, àmbit Enginyeria Industrial
CitationNoailly, J. Model developments for in silico studies of the lumbar spine biomechanics. Tesi doctoral, UPC, Departament de Ciència dels Materials i Enginyeria Metal·lúrgica, 2009. ISBN 9788469298497. DOI 10.5821/dissertation-2117-93381 . Available at: <http://hdl.handle.net/2117/93381>
Award-winningAward-winning
DLB.10123-2010
ISBN9788469298497
Other identifiershttp://www.tdx.cat/TDX-1229109-112855
Files | Description | Size | Format | View |
---|---|---|---|---|
JBN1de3.pdf | 7,278Mb | View/Open | ||
JBN2de3.pdf | 11,54Mb | View/Open | ||
JBN3de3.pdf | 4,619Mb | View/Open |