Mostra el registre d'ítem simple
Demagnetization diagnosis in permanent magnet synchronous motors under non-stationary speed conditions
dc.contributor.author | Riba Ruiz, Jordi-Roger |
dc.contributor.author | García Espinosa, Antonio |
dc.contributor.author | Romeral Martínez, José Luis |
dc.contributor.author | Cusidó Roura, Jordi |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica |
dc.date.accessioned | 2010-09-23T07:24:14Z |
dc.date.available | 2010-09-23T07:24:14Z |
dc.date.created | 2010-10 |
dc.date.issued | 2010-10 |
dc.identifier.citation | Riba, J. [et al.]. Demagnetization diagnosis in permanent magnet synchronous motors under non-stationary speed conditions. "Electric power systems research", Octubre 2010, vol. 80, núm. 10, p. 1277-1285. |
dc.identifier.issn | 0378-7796 |
dc.identifier.uri | http://hdl.handle.net/2117/9044 |
dc.description.abstract | Permanent magnet synchronous motors (PMSMs) are applied in high performance positioning and variable speed applications because of their enhanced features with respect to other AC motor types. Fault detection and diagnosis of electrical motors for critical applications is an active field of research. However, much research remains to be done in the field of PMSM demagnetization faults, especially when running under non-stationary conditions. This paper presents a time–frequency method specifically focused to detect and diagnose demagnetization faults in PMSMs running under non-stationary speed conditions, based on the Hilbert Huang transform. The effectiveness of the proposed method is proven by means of experimental results. |
dc.format.extent | 9 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Enginyeria mecànica::Motors::Motors hidràulics |
dc.subject.lcsh | Electric motors, Synchronous |
dc.title | Demagnetization diagnosis in permanent magnet synchronous motors under non-stationary speed conditions |
dc.type | Article |
dc.subject.lemac | Motors sicrònics |
dc.contributor.group | Universitat Politècnica de Catalunya. MCIA - Motion Control and Industrial Applications Research Group |
dc.identifier.doi | 10.1016/j.epsr.2010.04.010 |
dc.description.peerreviewed | Peer Reviewed |
dc.relation.publisherversion | http://linkinghub.elsevier.com/retrieve/pii/S037877961000101X |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 2604393 |
dc.description.version | Postprint (published version) |
local.citation.author | Riba, J.; Garcia, A.; Romeral, J.; Cusido, J. |
local.citation.publicationName | Electric power systems research |
local.citation.volume | 80 |
local.citation.number | 10 |
local.citation.startingPage | 1277 |
local.citation.endingPage | 1285 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [233]
-
Articles de revista [1.729]
-
Articles de revista [884]