Mostra el registre d'ítem simple

dc.contributor.authorRomero-Culleres, G.
dc.contributor.authorPeña Pitarch, Esteve
dc.contributor.authorJane Feixas, C.
dc.contributor.authorArnau Bartes, Ana
dc.contributor.authorMontesinos Muñoz, Jesús
dc.contributor.authorAbenoza Guardiola, Montserrat
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Mecànica
dc.date.accessioned2016-09-30T13:28:04Z
dc.date.available2016-11-30T01:30:21Z
dc.date.issued2015-11-20
dc.identifier.citationRomero-Culleres, G., Peña-Pitarch, E., Jane, C., Arnau, A., Montesinos, J., Abenoza, M. Intra-rater reliability and diagnostic accuracy of a new vaginal dynamometer to measure pelvic floor muscle strength in women with urinary incontinence. "Neurourology and urodynamics", Feb. 2017, Vol. 36, no. 2, p. 333-337.
dc.identifier.issn0733-2467
dc.identifier.urihttp://hdl.handle.net/2117/90349
dc.description.abstractThe first choice treatment in urinary incontinence (UI) is rehabilitation of the pelvic floor in order to improve muscle strength. However, no entirely reliable instruments for quantifying pelvic floor muscle (PFM) strength are currently available. Our aim was to test the intra-rater reliability and diagnostic accuracy of a new vaginal dynamometer for measuring PFM strength. Methods: Test-retest reliability study. One hundred and four women with stress urinary incontinence (SUI) were recruited. Patients were excluded if they had a history consistent with urge urinary incontinence or pelvic organ prolapse, pregnancy, previous urogynecological surgery, severe vaginal atrophy, or neurological conditions. The examination comprised digital palpation quantified by the modified Oxford scale and by two consecutive dynamometry measurements obtained using a new prototype dynamometer. This instrument comprises a speculum in which an inductive displacement sensor LVDTSM210.10.2.KTmodel, Schreiber) is attached to a spring of known stiffness constant (k). The intraclass correlation coefficient (ICC) was calculated to assess intra-rater reliability. Diagnostic accuracy was assessed using Receiver Operating Characteristics (ROC) curves analysis. Results: Of the 104 subjects included, 59.6% presented scores between 0–2 on the Oxford scale. Intra-rater reliability was 0.98 (95%CI: 0.97– 0.99). In the Bland & Altman plot, the distribution of disagreements was similar in the lowest and the highest strength values. The diagnostic accuracy of the dynamometer with regard to digital palpation showed an area under the curve of 0.85 (95%CI: 0.77–0.93). Conclusions: Our results suggest that this new vaginal dynamometer is a reliable and valid instrument for quantifying PFM strength.
dc.format.extent5 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria biomèdica::Aparells mèdics
dc.subject.lcshPelvic floor
dc.subject.lcshMuscle strength
dc.subject.lcshDynamometer
dc.subject.lcshUrinary incontinence
dc.subject.otherdynamometer
dc.subject.otherpelvic floor muscle strength
dc.subject.otherrehabilitation
dc.subject.otherurinary incontinence
dc.titleIntra-rater reliability and diagnostic accuracy of a new vaginal dynamometer to measure pelvic floor muscle strength in women with urinary incontinence
dc.typeArticle
dc.subject.lemacSòl pelvià
dc.subject.lemacDinamòmetre
dc.subject.lemacIncontinència urinària
dc.contributor.groupUniversitat Politècnica de Catalunya. SIR - Service and Industrial Robotics
dc.identifier.doi10.1002/nau.22924
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://onlinelibrary.wiley.com/doi/10.1002/nau.22924/abstract;jsessionid=54266E1F088FA5C21D005509C648895C.f03t04
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac18532855
dc.description.versionPostprint (published version)
dc.relation.projectidinfo:eu-repo/grantAgreement/MINECO//DPI2013-40882-P/ES/PRENSION Y MANIPULACION DIESTRA, MOVIL Y COOPERATIVA/
dc.contributor.covenanteeFundació Althaia
local.citation.authorRomero-Culleres, G.; Peña-Pitarch, E.; Jane, C.; Arnau, A.; Montesinos, J.; Abenoza, M.
local.citation.publicationNameNeurourology and urodynamics
local.citation.volume36
local.citation.number2
local.citation.startingPage333
local.citation.endingPage337


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple