Mostra el registre d'ítem simple

dc.contributor.authorTranquilli Leali, P.
dc.contributor.authorMerolli, A.
dc.contributor.authorRocchi, L.
dc.contributor.authorCatalano, F.
dc.contributor.authorPlanell Estany, Josep Anton
dc.contributor.authorEngel López, Elisabeth
dc.contributor.authorMartínez, E.
dc.contributor.authorSbernardori, M.C.
dc.contributor.authorMarceddu, S.
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Ciència dels Materials i Enginyeria Metal·lúrgica
dc.contributor.otherInstitut de Bioenginyeria de Catalunya
dc.date.accessioned2010-09-21T10:26:53Z
dc.date.available2010-09-21T10:26:53Z
dc.date.created2009
dc.date.issued2009
dc.identifier.citationMerolli, A. [et al.]. In vivo regeneration of rat sciatic nerve in a double-halved stitch-less guide: a pilot-study.. "Microsurgery", 2009, vol. 29, núm. 4, p. 310-318.
dc.identifier.issn0738-1085
dc.identifier.urihttp://hdl.handle.net/2117/8988
dc.description.abstractIt is about 20 years that tubular nerve guides have been introduced into clinical practice as a reliable alternative to autograft, in gaps notlonger-than 20 mm, bringing the advantage of avoiding donor site sacrifice and morbidity. There are limitations in the application of tubular guides. First, tubular structure in itself makes surgical implantation difficult; second, stitch sutures required to secure the guide may represent a site of unfavorable fibroblastic reaction; third, maximum length and diameter of the guide correlate with the occurrence of a poorer central vascularization of regenerated nerve. We report on the in vivo testing of a new concept of nerve-guide (named NeuroBox) which is double-halved, not-degradable, rigid, and does not require any stitch to be held in place, employing acrylate glue instead. Five male Wistar rats had the new guide implanted in a 4-mm sciatic nerve defect; two guides incorporated a surface constituted of microtrenches aligned longitudinally. Further five rats had the 4-mm gap left without repair. Contralateral intact nerves were used as controls. After 2 months, nerve regeneration occurred in all animals treated by the NeuroBox; fine blood vessels were well represented. There was no regeneration in the un-treated animals. Even if the limited number of animals does not allow to draw definitive conclusions, some result can be highlighted: an easy surgical technique was associated with the box-shaped guide and acrylate glue was easily applied; an adequate intraneural vascularization was found concurrently with the regeneration of the nerve and no adverse fibroblastic proliferation was present.
dc.format.extent9 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Ciències de la salut::Medicina
dc.subjectÀrees temàtiques de la UPC::Enginyeria química::Biotecnologia
dc.subject.lcshBioengineering
dc.subject.lcshMedicine
dc.titleIn vivo regeneration of rat sciatic nerve in a double-halved stitch-less guide: a pilot-study.
dc.typeArticle
dc.subject.lemacBioenginyeria
dc.subject.lemacMedicina
dc.contributor.groupUniversitat Politècnica de Catalunya. BBT - Biomaterials, Biomecànica i Enginyeria de Teixits
dc.identifier.doi10.1002/micr.20622
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac2580839
dc.description.versionPostprint (published version)
local.citation.authorMerolli, A.; Rocchi, L.; Catalano, F.; Planell, J.; Engel, E.; Martínez, E.; Sbernardori, M.; Marceddu, S.; Tranquilli Leali, P.
local.citation.publicationNameMicrosurgery
local.citation.volume29
local.citation.number4
local.citation.startingPage310
local.citation.endingPage318


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple