Mostra el registre d'ítem simple

dc.contributor.authorBogónez-Franco, Paco
dc.contributor.authorNescolarde Selva, Lexa Digna
dc.contributor.authorMcAdams, Eric
dc.contributor.authorRosell Ferrer, Francisco Javier
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2016-06-21T10:00:34Z
dc.date.issued2014-12-12
dc.identifier.citationBogónez-Franco, P., Nescolarde Selva, Lexa, McAdams, E., Rosell, F. Multifrequency right-side, localized and segmental BIA obtained with different bioimpedance analyzers. "Physiological measurement", 12 Desembre 2014, vol. 36, p. 85-106.
dc.identifier.issn0967-3334
dc.identifier.urihttp://hdl.handle.net/2117/88196
dc.description.abstractThe aim of this study is to compare two commercial bioimpedance analysers, BioparHom Z-Métrix and Impedimed SFB7, measuring the impedance of three different body segments. The segments measured were 'right-side' (or 'whole-body'), 'segmental right-lower limb' and 'localized longitudinal right-quadriceps'. The comparison was made on electrical models of each segment, including electrode–skin impedance, and in vivo on nine healthy volunteers. Both devices are designed to measure right-side impedances and, in the present study, as the length of the segment investigated decreased, the accuracy of the impedance measured was found to decrease. The accuracy of the devices was calculated via measurements performed on RC networks of known values. It was found that adding electrode–skin contact impedances in the electrical model affected the accuracy by both devices.
dc.format.extent22 p.
dc.language.isoeng
dc.publisherInstitute of Physics (IOP)
dc.subjectÀrees temàtiques de la UPC::Enginyeria biomèdica
dc.subject.lcshImpedance (Electricity)
dc.titleMultifrequency right-side, localized and segmental BIA obtained with different bioimpedance analyzers
dc.typeArticle
dc.subject.lemacImpedància (Electricitat)
dc.contributor.groupUniversitat Politècnica de Catalunya. IEB - Instrumentació Electrònica i Biomèdica
dc.identifier.doi10.1088/0967-3334/36/1/85
dc.description.peerreviewedPeer Reviewed
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac15346738
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorBogónez-Franco, P.; Nescolarde Selva, Lexa; McAdams, E.; Rosell, F.
local.citation.publicationNamePhysiological measurement
local.citation.volume36
local.citation.startingPage85
local.citation.endingPage106


Fitxers d'aquest items