ParaDIME: Parallel distributed infrastructure for minimization of energy for data centers

View/Open
Cita com:
hdl:2117/85255
Document typeArticle
Defense date2015-11-01
Rights accessOpen Access
Except where otherwise noted, content on this work
is licensed under a Creative Commons license
:
Attribution-NonCommercial-NoDerivs 3.0 Spain
Abstract
Dramatic environmental and economic impact of the ever increasing power and energy consumption of modern computing devices in data centers is now a critical challenge. On the one hand, designers use technology scaling as one of the methods to face the phenomenon called dark silicon (only segments of a chip function concurrently due to power restrictions). On the other hand, designers use extreme-scale systems such as teradevices to meet the performance needs of their applications which in turn increases the power consumption of the platform. In order to overcome these challenges, we need novel computing paradigms that address energy efficiency. One of the promising solutions is to incorporate parallel distributed methodologies at different abstraction levels.; The FP7 project ParaDIME focuses on this objective to provide different distributed methodologies (software-hardware techniques) at different abstraction levels to attack the power-wall problem. In particular, the ParaDIME framework will utilize: circuit and architecture operation below safe voltage limits for drastic energy savings, specialized energy-aware computing accelerators, heterogeneous computing, energy-aware runtime, approximate computing and power-aware message passing. The major outcome of the project will be a noval processor architecture for a heterogeneous distributed system that utilizes future device characteristics, runtime and programming model for drastic energy savings of data centers. Wherever possible, ParaDIME will adopt multidisciplinary techniques, such as hardware support for message passing, runtime energy optimization utilizing new hardware energy performance counters, use of accelerators for error recovery from sub-safe voltage operation, and approximate computing through annotated code. Furthermore, we will establish and investigate the theoretical limits of energy savings at the device, circuit, architecture, runtime and programming model levels of the computing stack, as well as quantify the actual energy savings achieved by the ParaDIME approach for the complete computing stack with the real environment.
Description
NOTICE: this is the author’s version of a work that was accepted for publication in "Microprocessors and Microsystems". Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in: Microprocessors and Microsystems, Volume 39, Issue 8 (November 2015). doi:10.1016/j.micpro.2015.06.005
CitationRethinagiri, S., Palomar, O., Sobe, Anita, Yalcin, G., Knauth, T., Titos, R., Prieto, P., Schneegaß, M., Cristal, A., Unsal, O., Felber, P., Fetzer, C., Milojevic, D. ParaDIME: Parallel distributed infrastructure for minimization of energy for data centers. "Microprocessors and microsystems", 01 Novembre 2015, vol. 39, núm. 8, p. 1174-1189.
ISSN0141-9331
Publisher versionhttp://www.sciencedirect.com/science/article/pii/S0141933115000848
Files | Description | Size | Format | View |
---|---|---|---|---|
ParaDIME.pdf | 3,860Mb | View/Open |