Mostra el registre d'ítem simple

dc.contributor.authorEscofet Soteras, Jaume
dc.contributor.authorBará Viñas, Salvador
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Òptica i Optometria
dc.date.accessioned2016-03-11T12:34:22Z
dc.date.available2016-03-11T12:34:22Z
dc.date.issued2015-12
dc.identifier.citationEscofet, J., Bará, S. Reducing the circadian input from self-luminous devices using hardware filters and software applications. "Lighting research & technology", Desembre 2015, vol. 49, núm. 4, p. 481-496.
dc.identifier.issn1477-1535
dc.identifier.urihttp://hdl.handle.net/2117/84205
dc.description.abstractThe widespread use of self-luminous devices at nighttime (cell-phones, computers, and tablets) raises some reasonable concerns regarding their effects on human physiology. Light at night is a known circadian disruptor, particularly at short visible wavelengths, and it seems advisable to have practical tools for tailoring the spectral radiance of these displays. We analyse two possible strategies to achieve this goal, using hardware filters or software applications. Overall, software applications seem to offer, at the present time, the best trade-offs for controlling the light spectra emitted by existing devices. We submit that such tools should be included as a standard feature on any self-luminous device and that their default settings should be established according to the best available knowledge on the circadian effects of light.
dc.format.extent16 p.
dc.language.isoeng
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::So, imatge i multimèdia::Dispositius de so, imatge i multimèdia
dc.subjectÀrees temàtiques de la UPC::Ciències de la visió::Òptica física::Llum
dc.subject.lcshElectroluminescent display systems
dc.subject.lcshCell phones
dc.subject.lcshComputers
dc.subject.lcshTablet computers
dc.subject.lcshHuman physiology
dc.subject.lcshLiquid crystal displays.
dc.subject.otherCircadian cycles
dc.subject.otherlight at night
dc.subject.otherself-luminous devices
dc.subject.otherhardware filters
dc.subject.othersoftware applications.
dc.titleReducing the circadian input from self-luminous devices using hardware filters and software applications
dc.typeArticle
dc.subject.lemacOrdinadors portàtils
dc.subject.lemacTelèfon mòbil
dc.subject.lemacDispositius optoelectrònics
dc.contributor.groupUniversitat Politècnica de Catalunya. GOAPI - Grup d'Òptica Aplicada i Processament d'Imatge
dc.identifier.doi10.1177/1477153515621946
dc.rights.accessOpen Access
local.identifier.drac17385018
dc.description.versionPreprint
local.citation.authorEscofet, J.; Bará, S.
local.citation.publicationNameLighting research & technology