Mostra el registre d'ítem simple

dc.contributor.authorRamos Fuentes, German A.
dc.contributor.authorCosta Castelló, Ramon
dc.contributor.authorOlm Miras, Josep Maria
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Matemàtiques
dc.date.accessioned2016-01-25T08:59:15Z
dc.date.available2016-08-01T00:30:52Z
dc.date.issued2015-07-01
dc.identifier.citationRamos, G.A., Costa-Castelló, R., Olm, Josep M. Precompensated Second Order Repetitive Control of an Active Filter Under Varying Network Frequency. "Asian journal of control", 01 Juliol 2015, vol. 17, núm. 4, p. 1243-1254.
dc.identifier.issn1561-8625
dc.identifier.urihttp://hdl.handle.net/2117/81931
dc.description.abstractNetwork frequency variations cause a dramatic performance decay in repetitive controller-based shunt active power filters. This problem may be solved by adapting the sampling period in order to keep the ratio between the network period and the sampling period at a constant value. However, these changes may yield closed-loop instability. The introduction of a precompensator that forces the plant to remain invariant despite sampling rate changes allows the use of standard LTI methods in control design and stability analysis as well. Moreover, in order to improve robustness in the face of network frequency estimation uncertainty and sampling time quantization, the regular repetitive controller is replaced by a high order one. Experimental results show the validity of the proposal.
dc.format.extent12 p.
dc.language.isoeng
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Informàtica
dc.subject.lcshAuomatic control
dc.subject.otherActive filters
dc.subject.otherrepetitive control
dc.subject.othervarying network frequency
dc.subject.otherselective harmonic compensation
dc.subject.otherinternal-model principle
dc.subject.othertime
dc.subject.otherdisturbances
dc.subject.othersystems
dc.subject.otherperiod
dc.titlePrecompensated Second Order Repetitive Control of an Active Filter Under Varying Network Frequency
dc.typeArticle
dc.subject.lemacControl automàtic
dc.contributor.groupUniversitat Politècnica de Catalunya. ACES - Control Avançat de Sistemes d'Energia
dc.identifier.doi10.1002/asjc.971
dc.description.peerreviewedPeer Reviewed
dc.rights.accessOpen Access
local.identifier.drac16844614
dc.description.versionPostprint (author's final draft)
local.citation.authorRamos, G.A.; Costa-Castelló, R.; Olm, Josep M.
local.citation.publicationNameAsian journal of control
local.citation.volume17
local.citation.number4
local.citation.startingPage1243
local.citation.endingPage1254


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple