Mostra el registre d'ítem simple

dc.contributor.authorGarcía González, Miguel Ángel
dc.contributor.authorFernández Chimeno, Mireya
dc.contributor.authorGuede Fernández, Federico
dc.contributor.authorFerrer Mileo, Víctor
dc.contributor.authorArgelagós Palou, Ariadna
dc.contributor.authorÁlvarez Gómez, Laura
dc.contributor.authorParrado Romero, Eva
dc.contributor.authorMoreno Sánchez, Jordi
dc.contributor.authorCapdevila, Lluis
dc.contributor.authorRamos Castro, Juan José
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2016-01-12T16:11:33Z
dc.date.available2016-01-12T16:11:33Z
dc.date.issued2015-12-14
dc.identifier.citationGarcia, M., Fernandez, M., Guede, F., Ferrer, V., Argelagós, A., Álvarez-Gómez, L., Parrado , E., Moreno, J., Capdevila, Ll., Ramos, J. A methodology to quantify the differences between alternative methods of heart rate variability measurement. "Physiological measurement", 14 Desembre 2015, núm. 37, p. 128-144.
dc.identifier.issn0967-3334
dc.identifier.urihttp://hdl.handle.net/2117/81315
dc.description.abstractThis work proposes a systematic procedure to report the differences between heart rate variability time series obtained from alternative measurements reporting the spread and mean of the differences as well as the agreement between measuring procedures and quantifying how stationary, random and normal the differences between alternative measurements are. A description of the complete automatic procedure to obtain a differences time series (DTS) from two alternative methods, a proposal of a battery of statistical tests, and a set of statistical indicators to better describe the differences in RR interval estimation are also provided. Results show that the spread and agreement depend on the choice of alternative measurements and that the DTS cannot be considered generally as a white or as a normally distributed process. Nevertheless, in controlled measurements the DTS can be considered as a stationary process.
dc.format.extent17 p.
dc.language.isoeng
dc.publisherInstitute of Physics (IOP)
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria biomèdica::Electrònica biomèdica::Electrònica en cardiologia
dc.subject.lcshHeart beat
dc.subject.lcshMedical electronics
dc.subject.otherHeart rate variability
dc.subject.otherSurrogate measurements
dc.subject.otherAgreement
dc.subject.otherStationarity
dc.subject.otherNormal distribution
dc.subject.otherRandomness
dc.titleA methodology to quantify the differences between alternative methods of heart rate variability measurement
dc.typeArticle
dc.subject.lemacCor -- Batecs
dc.subject.lemacElectrònica mèdica
dc.contributor.groupUniversitat Politècnica de Catalunya. IEB - Instrumentació Electrònica i Biomèdica
dc.identifier.doi10.1088/0967-3334/37/1/128
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://iopscience.iop.org/article/10.1088/0967-3334/37/1/128/meta;jsessionid=82644F56AB15A8989E3D666D543E0CF5.c4.iopscience.cld.iop.org
dc.rights.accessOpen Access
local.identifier.drac17364742
dc.description.versionPostprint (published version)
dc.relation.projectidinfo:eu-repo/grantAgreement/MICINN//PSI2011-29807-C02-02/ES/SISTEMA COMBINADO DE ANALISIS DE PARAMETROS FISIOLOGICOS, COGNITIVOS Y CONDUCTUALES BASADO EN PLATAFORMAS MOVILES/
dc.relation.projectidinfo:eu-repo/grantAgreement/ACUP/1PE/RecerCaixa 2013 - Marcadors estils vida
local.citation.authorGarcia, M.; Fernandez, M.; Guede, F.; Ferrer, V.; Argelagós, A.; Álvarez-Gómez, L.; Parrado, E.; Moreno, J.; Capdevila, Ll.; Ramos, J.
local.citation.publicationNamePhysiological measurement
local.citation.number37
local.citation.startingPage128
local.citation.endingPage144


Fitxers d'aquest items