dc.contributor.authorAlba, N
dc.contributor.authorGassó Domingo, Santiago
dc.contributor.authorLacorte Avila, M. Teresa
dc.contributor.authorBaldasano Recio, José María
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Ciència dels Materials i Enginyeria Metal·lúrgica
dc.date.accessioned2010-04-28T15:02:17Z
dc.date.available2010-04-28T15:02:17Z
dc.date.created1997-11
dc.date.issued1997-11
dc.identifier.citationAlba, N. [et al.]. Characterization of municipal solid waste incineration residues from facilities with different air pollution control systems. "Journal of the Air and Waste Management Association", Novembre 1997, vol. 47, p. 1170-1179.
dc.identifier.issn1047-3289
dc.identifier.urihttp://hdl.handle.net/2117/7085
dc.description.abstractMunicipal Solid Waste incinerator residues produced in two types of facilities were exhaustively characterized: granulometry, mineralogy, chemical composition, leaching behavior, and elemental distribution as a function of particle size. Air Pollution Control (APC) residues coming from a semi-dry scrubber have shown higher solubility than fly ashes originating in an Electrostatic Precipitator (ESP), as well as higher contents in volatile metals (Cd, Hg). Different metal speciation and distribution as a function of particle size have been found in fly ashes (ESP residues) and APC residues. In APC residues, heavy metals (with the exception of Hg) show a parabolic distribution with maxima in the smallest and largest particles, following the same profile as soluble salts. Metal distribution for APC residues exhibits that metals generally are not associated with silicate aluminate matrix. Results show the effect of adding lime to APC residues in metal speciation and distribution.
dc.format.extent10 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Desenvolupament humà i sostenible
dc.subject.lcshIntegrated solid waste management
dc.subject.lcshMunicipal solid waste incinerator residues
dc.titleCharacterization of municipal solid waste incineration residues from facilities with different air pollution control systems
dc.typeArticle
dc.subject.lemacResidus sòlids urbans -- Incineració
dc.contributor.groupUniversitat Politècnica de Catalunya. POLYCOM - Polimers i compòsits: tecnologia
dc.description.peerreviewedPeer Reviewed
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac1222066
dc.description.versionPostprint (published version)
local.citation.authorAlba, N.; Gassó, S.; Lacorte, M.; Baldasano, J.
local.citation.publicationNameJournal of the Air and Waste Management Association
local.citation.volume47
local.citation.startingPage1170
local.citation.endingPage1179