Mostra el registre d'ítem simple

dc.contributor.authorRosell Polo, Joan Ramon
dc.contributor.authorEscolà Agustí, Alexandre
dc.contributor.authorPalacín Roca, Jordi
dc.contributor.authorPallejà, Tomàs
dc.contributor.authorTresànchez, Marcel
dc.contributor.authorSanz Cortiella, Ricardo
dc.contributor.authorLlorens Calveras, Jordi
dc.contributor.authorRibes-Dasi, Manel
dc.contributor.authorMasip, Joan
dc.contributor.authorArnó Satorra, Jaume
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Agroalimentària i Biotecnologia
dc.date.accessioned2010-02-10T17:44:38Z
dc.date.available2010-02-10T17:44:38Z
dc.date.created2007-08
dc.date.issued2007-08
dc.identifier.citationPalacín, J. [et al.]. Real-time tree foliage surface estimation using a ground laser scanner.. "IEEE transactions on instrumentation and measurement", Agost 2007, vol. 56, núm. 4, p. 1377-1383.
dc.identifier.issn0018-9456
dc.identifier.urihttp://hdl.handle.net/2117/6335
dc.description.abstractThe optimization of most pesticide and fertilizer applications is based on overall grove conditions. In this paper, we propose a measurement system to estimate the foliage surface of a tree crop. The system is based on a ground laser scanner that estimates the volume of the trees and then extrapolates their leaf area using simple and fast algorithms to allow true real-time operation. Tests with pear trees demonstrated that the relation between the volume and the foliage can be interpreted as linear with a coefficient of correlation (R) of 0.81, and the foliage surface can be estimated from this volume with an average error less than 6%.
dc.format.extent7 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria agroalimentària::Agricultura
dc.subject.lcshPesticides - Physiological effects
dc.subject.lcshAgriculture--Remote sensing.
dc.titleReal-time tree foliage surface estimation using a ground laser scanner.
dc.typeArticle
dc.subject.lemacPlaguicides -- Efectes fisiològics
dc.subject.lemacTeledetecció -- Aplicacions agrícoles
dc.contributor.groupUniversitat Politècnica de Catalunya. POCIÓ - Protecció Vegetal
dc.identifier.doi10.1109/TIM.2007.900126
dc.rights.accessOpen Access
local.identifier.drac1824476
dc.description.versionPostprint (published version)
local.citation.authorPalacín, J.; Pallejà, T.; Tresanchez, M.; Sanz, R.; Llorens, J.; Ribes-Dasi, M.; Masip, J.; Arnó, J.; Escolà, A.; Rosell, J.
local.citation.publicationNameIEEE transactions on instrumentation and measurement
local.citation.volume56
local.citation.number4
local.citation.startingPage1377
local.citation.endingPage1383


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple