Anomaly detection in gas turbines using outlet energy analysis with cluster-based matrix profile
View/Open
Cita com:
hdl:2117/405434
Document typeArticle
Defense date2024-01-30
Rights accessOpen Access
Except where otherwise noted, content on this work
is licensed under a Creative Commons license
:
Attribution 4.0 International
Abstract
Gas turbines play a key role in generating power. It is really important that they work efficiently, safely, and reliably. However, their performance can be adversely affected by factors such as component wear, vibrations, and temperature fluctuations, often leading to abnormal patterns indicative of potential failures. As a result, anomaly detection has become an area of active research. Matrix Profile (MP) methods have emerged as a promising solution for identifying significant deviations in time series data from normal operational patterns. While most existing MP methods focus on vibration analysis of gas turbines, this paper introduces a novel approach using the outlet power signal. This modified approach, termed Cluster-based Matrix Profile (CMP) analysis, facilitates the identification of abnormal patterns and subsequent anomaly detection within the gas turbine engine system. Significantly, CMP analysis not only accelerates processing speed, but also provides user-friendly support information for operators. The experimental results on real-world gas turbines demonstrate the effectiveness of our approach in the early detection of anomalies and potential system failures.
CitationBagherzade, M. [et al.]. Anomaly detection in gas turbines using outlet energy analysis with cluster-based matrix profile. "Energies", 30 Gener 2024, vol. 17, núm. 3, article 653.
ISSN1996-1073
Publisher versionhttps://www.mdpi.com/1996-1073/17/3/653
Files | Description | Size | Format | View |
---|---|---|---|---|
energies-17-00653.pdf | 12,50Mb | View/Open |