Tolerance to residual astigmatism of an isofocal intraocular lens
View/Open
PLANO_Astigmatism_Graefes_Final_revision_CC.pdf (361,0Kb) (Restricted access)
Request copy
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Cita com:
hdl:2117/402120
Document typeArticle
Defense date2023-11-11
PublisherSpringer Nature
Rights accessRestricted access - publisher's policy
(embargoed until 2024-11-11)
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
Purpose To evaluate the impact of residual astigmatism on the optical and visual performance of an enhanced-monofocal isofocal intraocular lens (EM Isopure, BVI medical, Belgium) compared to a monofocal one (Micropure, BVI medical, Belgium). Methods Laboratory investigation and prospective, comparative and randomized clinical study. Optical quality was assessed on an optical bench for 2.0, 3.0, and 4.5 mm pupils. The effect of residual astigmatism was investigated from through-focus images recorded with increasing amounts of regular positive astigmatism induced with a deformable mirror. To evaluate the impact of residual astigmatism, 28 eyes of 28 patients were randomly assigned to either group. Residual astigmatism was induced with positive and negative cylinder lenses at 90 and 180°. Visual acuity (VA) was measured at each step. Results The optical performance of both IOLs was quite similar for 2.0 and 3.0 mm pupils. For 4.5-mm pupil, the EM Isopure showed a significant reduction of its optical quality in comparison with the monofocal IOL. When visual performance was evaluated, no statistically significant differences were found for any power of induced astigmatism. More differences were found when positive induced astigmatism was compared within each group, and VA was better when the astigmatism was induced at 180° vs. 90°. The greatest differences were found for and induced positive astigmatism of¿+¿1.50D (p¿=¿0.009 for Isopure and p¿=¿0.023 for Micropure). Conclusions The tolerance to residual astigmatism of the EM Isopure lens is similar to that of a reference monofocal lens with pupils up to 3.5 mm.
CitationPérez, L. [et al.]. Tolerance to residual astigmatism of an isofocal intraocular lens. "Graefe's archive for clinical and experimental ophthalmology", April 2024, vol. 262, p. 1169-1180.