Dose assesment with fast Monte Carlo codes in interventional radiology
View/Open
Cita com:
hdl:2117/399247
Document typeArticle
Defense date2023-10-11
Rights accessOpen Access
Except where otherwise noted, content on this work
is licensed under a Creative Commons license
:
Attribution-NonCommercial-NoDerivs 4.0 International
ProjectDOSIMETRIA PERSONAL EN LINEA (ONLINE) UTILIZANDO METODOS COMPUTACIONALES (AEI-PCIN-2017-044)
CONCERT - European Joint Programme for the Integration of Radiation Protection Research (EC-H2020-662287)
CONCERT - European Joint Programme for the Integration of Radiation Protection Research (EC-H2020-662287)
Abstract
This study presents the performance of two fast Monte Carlo codes, PENELOPE/penEasyIR and MCGPU-IR in order to assess operator doses in interventional radiology. In particular, it aims to validate the calculations when workers are protected with shielding located between the patient and the operator. The experiments are performed in a calibration laboratory and measurements are gathered using Thermo EPD and Mirion DMC personal active dosemeters. Calculation efficiency of the fast Monte Carlo codes is approximately four orders of magnitude greater than for a standard Monte Carlo code. Satisfactory agreement between measurements and calculations is shown.
CitationGarcia, V. [et al.]. Dose assesment with fast Monte Carlo codes in interventional radiology. "Radiation protection dosimetry", 11 Octubre 2023, vol. 199, núm. 15-16, p. 1813-1817.