Ammonium recovery and concentration from synthetic wastewater using a poly(4-methyl-1-pentene) (PMP) liquid–liquid membrane contactor: Flux performance and mass transport characterization
View/Open
Aguilar-Moreno+et+al.-Manuscript_Final.docx (1,300Mb) (Restricted access)
Request copy
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Cita com:
hdl:2117/395412
Document typeArticle
Defense date2023-12-01
PublisherElsevier
Rights accessRestricted access - publisher's policy
(embargoed until 2025-12-01)
Except where otherwise noted, content on this work
is licensed under a Creative Commons license
:
Attribution-NonCommercial-NoDerivs 4.0 International
Abstract
Hollow fiber membrane contactors are a promising technology for the removal and recovery of ammonia from liquid effluents. However, a better understanding of the process engineering (e.g. mass transport of ammonia over water) and performance optimization is required. In this study, the performance of a hollow fibre liquid–liquid membrane contactor (HF-LLMC), incorporating a new polymer chemistry (i.e., poly (4-methyl-1-pentene (PMP) and an asymmetric fibre structure, for the recovery and concentration of ammonium from synthetic aqueous solutions, was investigated. The influence of the feed and acid flow rates was evaluated experimentally by determining the overall mass transfer coefficient (), the ammonium recovery as a function of time and the acid consumption. In addition, the experimental results were fitted to a mathematical model to determine the membrane permeabilities to ammonia () and water () and identify the mass transfer resistance regime. The highest values experimentally obtained were in the range of 3·10–3 to 3.51·10–3 m/h with corresponding ammonia recovery rates of 94 and 96.2% after 10 h, operating at a feed and acid flow rates of 180 L h-1 and 500 L h-1, respectively, which are in the upper range of the HF-LLMC literature. The overall results of this study were not only the upper range of the HF-LLMC ammonia recovery literature but a much-lower water transport was confirmed indirectly by the concentration factor (CF) values obtained experimentally. The remarkable selectivity of the membrane towards ammonia over water (i.e., = 87–180 L m–2h-1 bar-1 and = 1.2–1.4·10–3 L m-2 h-1 bar-1 at NTP conditions) is attributed to the asymmetrical membrane structure and the polymer chemistry (i.e., PMP). The proven high ammonia selectivity of the HF-LLMC makes it a promising technology for the recovery and concentration of ammonium from urban (e.g. wastewaters) and industrial (e.g. soda ash and fertilizers production) diluted streams.
CitationAguilar, M. [et al.]. Ammonium recovery and concentration from synthetic wastewater using a poly(4-methyl-1-pentene) (PMP) liquid–liquid membrane contactor: Flux performance and mass transport characterization. "Separation and purification technology", 1 Desembre 2023, vol. 326, núm. 124657.
ISSN1873-3794
Publisher versionhttps://www.sciencedirect.com/science/article/pii/S1383586623015654
Files | Description | Size | Format | View |
---|---|---|---|---|
Aguilar-Moreno+et+al.-Manuscript_Final.docx | 1,300Mb | Microsoft Word 2007 | Restricted access |