Cerca
Ara es mostren els items 1-6 de 6
Monte Carlo dosimetry for forthcoming clinical trials in x-ray microbeam radiation therapy
(2010)
Article.
Accés obert
Article.
Accés obert
The purpose of this work is to define safe irradiation protocols in microbeam
radiation therapy. The intense synchrotron-generated x-ray beam used for the
treatment is collimated and delivered in an array of 50 μm-sized ...
Technical Note: Study of the electron transport parameters used in penelope for the Monte Carlo simulation of Linac targets
(2015-06-01)
Article.
Accés restringit per política de l'editorial
Article.
Accés restringit per política de l'editorial
Purpose: The Monte Carlo simulation of electron transport in Linac targets using the condensed history technique is known to be problematic owing to a potential dependence of absorbed dose distributions on the electron ...
Microplane constitutive model M4L for concrete. I: Theory
(2013)
Article.
Accés restringit per política de l'editorial
Article.
Accés restringit per política de l'editorial
The present, Part I, of this two-part study presents a new microplane constitutive model for simulating
the fracture and damage behavior of concrete materials subjected to various loadings. The concept of
stress–strain ...
Microplane constitutive model M4L for concrete. II: Calibration and validation
(2013)
Article.
Accés restringit per política de l'editorial
Article.
Accés restringit per política de l'editorial
This paper, Part II of a two-part study, presents the numerical calibration and validation of the microplane
constitutive model M4L for concrete formulated in the preceding part. The model parameters are firstly
calibrated ...
Spencer–Attix water/medium stopping-power ratios for the dosimetry of proton pencil beams
(2013-03-21)
Article.
Accés restringit per política de l'editorial
Article.
Accés restringit per política de l'editorial
This paper uses Monte Carlo simulations to calculate the Spencer-Attix water/medium stopping-power ratios (sw, med) for the dosimetry of scanned proton pencil beams. It includes proton energies from 30 to 350 MeV and typical ...
A general analytical solution to the geometrical problem of field matching in radiotherapy
(2009)
Article.
Accés restringit per política de l'editorial
Article.
Accés restringit per política de l'editorial
Purpose: Several authors studied the problem of geometrical matching of fields produced by
medical linear accelerators. However, a general solution has yet to be published. Currently available