Show simple item record

dc.contributor.authorGrossi, Claudia
dc.contributor.authorRábago, Daniel
dc.contributor.authorSainz, Carlos
dc.contributor.authorCurcoll Masanes, Roger
dc.contributor.authorOtáhal, Petr
dc.contributor.authorFialova, Eliska
dc.contributor.authorQuindós, Luis
dc.contributor.authorVargas Drechsler, Arturo
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Física
dc.contributor.otherUniversitat Politècnica de Catalunya. Doctorat en Enginyeria Nuclear i de les Radiacions Ionitzants
dc.contributor.otherUniversitat Politècnica de Catalunya. Institut de Tècniques Energètiques
dc.date.accessioned2023-09-15T09:44:31Z
dc.date.available2023-09-15T09:44:31Z
dc.date.issued2023-05-31
dc.identifier.citationGrossi, C. [et al.]. Characterizing the automatic radon flux transfer standard system autoflux: laboratory calibration and field experiments. "Atmospheric measurement techniques", 31 Maig 2023, vol. 16, núm. 10, p. 2655-2672.
dc.identifier.issn1867-8548
dc.identifier.urihttp://hdl.handle.net/2117/393545
dc.description.abstractHigh-quality, long-term measurements of terrestrial trace gas emissions are important for investigations of atmospheric, geophysical and biological processes to help mitigate climate change and protect the environment and the health of citizens. High-frequency terrestrial fluxes of the radioactive noble gas 222Rn, in particular, are useful for validating radon flux maps and used to evaluate the performance of regional atmospheric models, to improve greenhouse gas emission inventories (by the radon tracer method) and to determine radon priority areas for radiation protection goals. A new automatic radon flux system (Autoflux) was developed as a transfer standard (TS) to assist with establishing a traceability chain for field-based radon flux measurements. The operational characteristics and features of the system were optimized based on a literature review of existing flux measurement systems. To characterize and calibrate Autoflux, a bespoke radon exhalation bed (EB) facility was also constructed with the intended purpose of providing a constant radon exhalation under a specific set of controlled laboratory conditions. The calibrated Autoflux was then used to transfer the derived calibration to a second continuous radon flux system under laboratory conditions; both instruments were then tested in the field and compared with modeled fluxes. This paper presents (i) a literature review of state-of-the-art radon flux systems and EB facilities; (ii) the design, characterization and calibration of a reference radon EB facility; (iii) the design, characterization and calibration of the Autoflux system; (iv) the calibration of a second radon flux system (INTE_Flux) using the EB and Autoflux, with a total uncertainty of 9% (k=1) for an average radon flux of ~1800mBqm-2s-1 under controlled laboratory conditions; and (v) an example application of the calibrated TS and INTE_Flux systems for in situ radon flux measurements, which are then compared with simulated radon fluxes. Calibration of the TS under different environmental conditions and at lower reference fluxes will be the subject of a separate future investigation.
dc.format.extent18 p.
dc.language.isoeng
dc.publisherEuropean Geosciences Union (EGU)
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectÀrees temàtiques de la UPC::Física
dc.subject.lcshEnvironmental geology
dc.subject.lcshGeochemistry
dc.titleCharacterizing the automatic radon flux transfer standard system autoflux: laboratory calibration and field experiments
dc.typeArticle
dc.subject.lemacGeologia del medi ambient
dc.subject.lemacGeoquímica
dc.contributor.groupUniversitat Politècnica de Catalunya. IONHE - Ionising Radiation, Health and Environment
dc.identifier.doi10.5194/amt-16-2655-2023
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://amt.copernicus.org/articles/16/2655/2023/
dc.rights.accessOpen Access
local.identifier.drac36638671
dc.description.versionPostprint (published version)
dc.relation.projectidEMPIR-JRP-19ENV01-traceRadon
local.citation.authorGrossi, C.; Rábago, D.; Sainz, C.; Curcoll, R.; Otáhal, P.; Fialova, E.; Quindós, L.; Vargas, A.
local.citation.publicationNameAtmospheric measurement techniques
local.citation.volume16
local.citation.number10
local.citation.startingPage2655
local.citation.endingPage2672


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record