Show simple item record

dc.contributor.authorHranitzky, Christian
dc.contributor.authorNaber, Christian
dc.contributor.authorAslan, Julia
dc.contributor.authorDuch Guillen, María Amor
dc.contributor.authorHaninger, Thomas
dc.contributor.authorKneževic, Zeljka
dc.contributor.otherUniversitat Politècnica de Catalunya. Institut de Tècniques Energètiques
dc.date.accessioned2023-06-08T08:10:16Z
dc.date.issued2023-04-01
dc.identifier.citationHranitzky, C. [et al.]. Low dose response results and detection limits of the EURADOS intercomparison IC2021area for passive H*(10) area dosemeters. "Radiation measurements", 1 Abril 2023, vol. 163, núm. 106935.
dc.identifier.issn1350-4487
dc.identifier.urihttp://hdl.handle.net/2117/388373
dc.description.abstractThe EURADOS intercomparison IC2021area with its main focus on low dose measurements was carried out between May 2021 and April 2022 for passive H*(10) area dosimetry systems. Three measurement conditions were provided at locations of the Karlsruhe Institute of Technology: 3-months indoor, 3-months outdoor and 6-months outdoor. The challenge for the 65 participating dosimetry systems of this intercomparison was measuring additionally irradiated low dose 137Cs gamma radiation of 150 µSv and 300 µSv. Despite the comparably high background dose values between about 200 µSv and 1600 µSv, more than 90% of the resulting response values of the irradiated dosemeters were within the recommended ISO 14146 response limits. The calculated detection limits of the participating dosimetry systems were in most cases clearly below the desired value of 150 µSv of this intercomparison.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectÀrees temàtiques de la UPC::Energies
dc.subject.lcshDosimeters
dc.subject.otherEURADOS
dc.subject.otherIntercomparison
dc.subject.otherArea dosimetry
dc.subject.otherPassive dosemeter
dc.subject.otherDosemeter response
dc.subject.otherBackground dose
dc.subject.otherDetection limit
dc.titleLow dose response results and detection limits of the EURADOS intercomparison IC2021area for passive H*(10) area dosemeters
dc.typeArticle
dc.subject.lemacDosímetres
dc.contributor.groupUniversitat Politècnica de Catalunya. IONHE - Ionising Radiation, Health and Environment
dc.identifier.doi10.1016/j.radmeas.2023.106935
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/abs/pii/S1350448723000367
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac35733352
dc.description.versionPostprint (published version)
dc.date.lift2024-12
local.citation.authorHranitzky, C.; Naber, C.; Aslan, J.; Duch, M.; Haninger, T.; Kneževic, Z.
local.citation.publicationNameRadiation measurements
local.citation.volume163
local.citation.number106935


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record