Show simple item record

dc.contributor.authorBas Calopa, Pau
dc.contributor.authorRiba Ruiz, Jordi-Roger
dc.contributor.authorMoreno Eguilaz, Juan Manuel
dc.contributor.otherUniversitat Politècnica de Catalunya. Doctorat en Enginyeria Elèctrica
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2023-05-11T12:03:29Z
dc.date.available2023-05-11T12:03:29Z
dc.date.issued2023-03-22
dc.identifier.citationBas, P.; Riba, J.; Moreno-Eguilaz, J.M. Analyzing the effect of dynamic pressure drop on corona discharges for aircraft applications. "Aerospace", 22 Març 2023, vol. 10, núm. 3, article 320.
dc.identifier.issn2226-4310
dc.identifier.urihttp://hdl.handle.net/2117/387297
dc.description.abstractThe combination of the low-pressure environment found in aircraft systems and the gradual electrification of aircraft increases the risk of electrical discharges occurrence. This is an undesirable situation that compromises aircraft safety and complicates maintenance operations. Experimental data are needed to understand this problem. However, most of the published studies are based on static pressure conditions, but aircraft systems are exposed to dynamic pressure conditions, especially during the climb and descent phases of flight. This paper analyzes the effect of dynamic pressure during the climb phase on the corona inception voltage because this phase experiences the worst pressure drop rate. The experimental evidence presented in this paper shows that within the analyzed pressure drop rate range, the dynamic pressure conditions do not have a significant effect on the corona inception value under typical conditions found in aircraft systems during the climb phase.
dc.language.isoeng
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectÀrees temàtiques de la UPC::Enginyeria elèctrica
dc.subject.lcshAircraft industry
dc.subject.otherCorona discharges
dc.subject.otherLow pressure
dc.subject.otherPressure change
dc.subject.otherHybrid aircrafts
dc.subject.otherElectric aircrafts
dc.titleAnalyzing the effect of dynamic pressure drop on corona discharges for aircraft applications
dc.typeArticle
dc.subject.lemacIndústria aeronàutica
dc.contributor.groupUniversitat Politècnica de Catalunya. MCIA - Motion Control and Industrial Applications Research Group
dc.identifier.doi10.3390/aerospace10030320
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://www.mdpi.com/2226-4310/10/3/320
dc.rights.accessOpen Access
local.identifier.drac35614630
dc.description.versionPostprint (published version)
local.citation.authorBas, P.; Riba, J.; Moreno-Eguilaz, J.M.
local.citation.publicationNameAerospace
local.citation.volume10
local.citation.number3, article 320


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record