Mostra el registre d'ítem simple

dc.contributor.authorLu, Yonggang
dc.contributor.authorZhao, Weiqiang
dc.contributor.authorPresas Batlló, Alexandre
dc.contributor.authorZhu, Rongsheng
dc.contributor.authorWang, Zhengwei
dc.contributor.otherUniversitat Politècnica de Catalunya. Doctorat en Enginyeria Mecànica, Fluids i Aeronàutica
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Mecànica de Fluids
dc.date.accessioned2023-02-02T08:24:02Z
dc.date.issued2022-05-25
dc.identifier.citationLu, Y. [et al.]. Shutdown idling performance of the nuclear main coolant pump under station blackout accident: An optimization study. "Proceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy", 25 Maig 2022, vol. 237, núm. 1, p. 79-97.
dc.identifier.issn2041-2967
dc.identifier.urihttp://hdl.handle.net/2117/381674
dc.description.abstractLead-cooled fast reactor (LFR) is an important reactor type of the Generation IV nuclear energy, and the main coolant pump (MCP) is the only and most critical power equipment in primary circuit of LFR. The shutdown idling performance of the MCP, is one of the most important safety indicators in the event of a station blackout accident. When the motor loses its power supply, the MCP needs to run under the inertia of the flywheel to ensure the coolant flow for a short time. This study mainly focuses on the idling mathematical model of the MCP under power failure accidents. In this study, taking the shutdown idling performance of the MCP as the optimization goal, the parametric optimization analysis of the impeller and diffuser structure of the MCP was carried out. Specifically, based on the platform ISIGHT, the software of CFturbo, TurboGrid, CFX, Matlab and FLOWMASTER are systematically integrated, the automated 3D modeling, automatic meshing and automatic CFD calculation of different hydraulic model of the MCP are realized. And the neural network mathematical model between the geometric parameters of MCP and the idling performance indicators is established. The study shows that there is a strong linear relationship between the idling performance of the MCP and its head and shaft power, and meridian parameters of ¿ß2, Z1, F1h and the radial surface parameters of ¿ß1 and ¿ß2, Z1 and F1h have the greatest impact on the idling performance of MCP.
dc.format.extent19 p.
dc.language.isoeng
dc.publisherSAGE publishing
dc.subjectÀrees temàtiques de la UPC::Física
dc.subject.lcshNuclear energy
dc.titleShutdown idling performance of the nuclear main coolant pump under station blackout accident: An optimization study
dc.typeArticle
dc.subject.lemacEnergia nuclear
dc.contributor.groupUniversitat Politècnica de Catalunya. FLUIDS - Enginyeria de Fluids
dc.identifier.doi10.1177/09576509221105230
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://journals.sagepub.com/doi/10.1177/09576509221105230
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac33807735
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorLu, Y.; Zhao, W.; Presas, A.; Zhu, R.; Wang, Z.
local.citation.publicationNameProceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy
local.citation.volume237
local.citation.number1
local.citation.startingPage79
local.citation.endingPage97


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple