Intercomparison IC2021area of passive area dosimetry systems

Thumbnail
View/Open
EURADOS Report 2022-01.pdf (5,556Mb)
 
10.12768/55t9-ms26
 
  View UPCommons Usage Statistics
  LA Referencia / Recolecta stats
Includes usage data since 2022
Cita com:
hdl:2117/372249

Show full item record
Duch Guillen, María AmorMés informacióMés informacióMés informació
Hranitzky, Christian
Kneževic, Zeljka
Naber, Christian
Haninger, Thomas
Aslan, Julia
Document typePart of book or chapter of book
Defense date2022-05-02
PublisherEuropean Radiation Dosimetry e. V.
Rights accessOpen Access
Attribution-NonCommercial-NoDerivs 4.0 International
This work is protected by the corresponding intellectual and industrial property rights. Except where otherwise noted, its contents are licensed under a Creative Commons license : Attribution-NonCommercial-NoDerivs 4.0 International
Abstract
The EURADOS intercomparison IC2021area was carried out between May 2021 and April 2022 for 66 participating passive H*(10) area dosimetry systems from 47 different institutes and monitoring services. Three measurement conditions were provided at locations of the Karlsruhe Institute of Technology: 3-months indoor, 3-months outdoor and 6-months outdoor. The challenge of this intercomparison was measuring additionally irradiated low dose radiation. Six dosemeters of each participating system were irradiated with Cs-137 gamma reference radiation: Three dosemeters with 150 µSv and three dosemeters with 300 µSv. Another six dosemeters of each participating system were not irradiated and were used for background dose subtraction. Typical values of the measured background dose were between 200 µSv and 450 µSv with a few significantly higher values up to 1.6 mSv. Despite the challenge of the low reference dose values, more than 90 % of the resulting response values of the irradiated dosemeters were within the recommended ISO 14146 trumpet curve response limits.
CitationDuch, M. [et al.]. Intercomparison IC2021area of passive area dosimetry systems. A: "Intercomparison IC2021area of passive area dosimetry systems". Neuherberg: European Radiation Dosimetry e. V., 2022, 
URIhttp://hdl.handle.net/2117/372249
DOI10.12768/55t9-ms26
ISBN978-3-943701-31-9
Publisher versionhttps://eurados.sckcen.be/
Other identifiershttps://eurados.sckcen.be/sites/eurados/files/uploads/Report-Publications/Reports/2022/EURADOS%20Report%202022-01.pdf
Collections
  • DRM - Dosimetria i Radiofísica Mèdica - Capítols de llibre [2]
  • INTE - Institut de Tècniques Energètiques - Capítols de llibre [3]
  View UPCommons Usage Statistics

Show full item record

FilesDescriptionSizeFormatView
EURADOS Report 2022-01.pdf5,556MbPDFView/Open

Browse

This CollectionBy Issue DateAuthorsOther contributionsTitlesSubjectsThis repositoryCommunities & CollectionsBy Issue DateAuthorsOther contributionsTitlesSubjects

© UPC Obrir en finestra nova . Servei de Biblioteques, Publicacions i Arxius

info.biblioteques@upc.edu

  • About This Repository
  • Metadata under:Metadata under CC0
  • Contact Us
  • Send Feedback
  • Privacy Settings
  • Inici de la pàgina