Indoor monitoring system based on ARQ signaling generated by a Visible Light Communication link
View/Open
Indoor_monitoring_system_based_on_ARQ_signaling_generated_by_a_Visible_Light_Communication_link.pdf (4,649Mb) (Restricted access)
Request copy
Què és aquest botó?
Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:
- Disposem del correu electrònic de l'autor
- El document té una mida inferior a 20 Mb
- Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
Cita com:
hdl:2117/367985
Document typeConference lecture
Defense date2021
PublisherInstitute of Electrical and Electronics Engineers (IEEE)
Rights accessRestricted access - publisher's policy
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
Visible Light Communications (VLC) is a candidate technology that complements the benefits of radio communication networks, particularly in those situations where a low-cost solution using license-free spectrum is required to enable ultra-dense deployments of indoor small cells. However, the main drawback that VLC has when compared to wireless communications on RF bands is that, in presence of obstacles between the transmitter and the receiver, full-blockage events are likely to happen as the power received on reflections is much weaker than the power of the blocked line-of-sight link. In this paper, we take advantage of this phenomenon and study the effect that different activities performed by people in the service area to-be-monitored have on the Automatic Repeat reQuest (ARQ) signaling of the VLC link. Based on the presented experimental studies, it is possible to conclude that different relevant events are able to be detected correctly according to the statistics of the ARQ signaling that is collected from the ongoing VLC transmission.
CitationBas, J. [et al.]. Indoor monitoring system based on ARQ signaling generated by a Visible Light Communication link. A: IEEE Global Communications Conference. "2021 IEEE Global Communications Conference (GLOBECOM): Madrid, Spain 7-11 December 2021: proceedings". Institute of Electrical and Electronics Engineers (IEEE), 2021, ISBN 978-1-7281-8104-2. DOI 10.1109/GLOBECOM46510.2021.9685169.
ISBN978-1-7281-8104-2
Publisher versionhttps://ieeexplore.ieee.org/document/9685169
Files | Description | Size | Format | View |
---|---|---|---|---|
Indoor_monitori ... ght_Communication_link.pdf | 4,649Mb | Restricted access |