Show simple item record

dc.contributor.authorSerrano Fontova, Alexandre
dc.contributor.authorMartínez Velasco, Juan Antonio
dc.contributor.authorCasals Torrens, Pau
dc.contributor.authorBosch Tous, Ricardo
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica
dc.date.accessioned2022-01-27T12:24:12Z
dc.date.available2022-01-27T12:24:12Z
dc.date.issued2021-12-01
dc.identifier.citationSerrano, A. [et al.]. A robust islanding detection method with zero-non-detection zone for distribution systems with DG. "International journal of electrical power and energy systems", 1 Desembre 2021, vol. 133, núm. 107247, p. 107247:1-107247: 16.
dc.identifier.issn0142-0615
dc.identifier.urihttp://hdl.handle.net/2117/360851
dc.description.abstractThis paper proposes a strategy for detecting unintentional islanding operations (IOs) in distribution networks (DNs) with distributed generation (DG), which eliminating the non-detection zone (NDZ). This hybrid method achieves a zero-NDZ by taking advantage of both passive and active methodologies for an inverter-based DG scenario. The passive-based part of the proposed method considers settings with low thresholds and is activated whenever they are surpassed. The following step uses a three-phase static RC load. This load is connected to intentionally force the frequency and its derivative to exceed the established thresholds. Thus, the events with zero power imbalance can be identified. Unlike other existing methods, this technique does not degrade the power quality (PQ) and does not require DG output power curtailment. The evaluation of the proposed strategy has been carried out through an extensive set of scenarios considering both islanding and non-islanding events. The islanding detection capabilities of the proposed method have been explored considering a custom-made DN test system and the test system recommended by the IEEE 929-2000 standard. The proposed method has a simple implementation, requires a low level of computational complexity, provides a high degree of reliability, and assures fast islanding detection.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectÀrees temàtiques de la UPC::Enginyeria elèctrica
dc.subject.lcshSmart power grids
dc.subject.lcshRenewable energy sources
dc.subject.lcshElectric power distribution
dc.subject.otherDistribution networks
dc.subject.otherDistributed generation
dc.subject.otherIslanding detection
dc.subject.otherSmart grids
dc.titleA robust islanding detection method with zero-non-detection zone for distribution systems with DG
dc.typeArticle
dc.subject.lemacXarxes elèctriques intel·ligents
dc.subject.lemacEnergies renovables
dc.subject.lemacEnergia elèctrica--Distribució
dc.contributor.groupUniversitat Politècnica de Catalunya. InSup - Grup de Recerca en Interacció de Superfícies en Bioenginyeria i Ciència dels Materials
dc.identifier.doi10.1016/j.ijepes.2021.107247
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S0142061521004865
dc.rights.accessOpen Access
local.identifier.drac32010642
dc.description.versionPostprint (published version)
local.citation.authorSerrano, A.; Martinez, J.; Casals-Torrens, P.; Bosch, R.
local.citation.publicationNameInternational journal of electrical power and energy systems
local.citation.volume133
local.citation.number107247
local.citation.startingPage107247:1
local.citation.endingPage107247: 16
dc.description.sdgObjectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant::7.3 - Per a 2030, duplicar la taxa mundial de millora de l’eficiència energètica
dc.description.sdgObjectius de Desenvolupament Sostenible::7 - Energia Assequible i No Contaminant
dc.description.sdgObjectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats Sostenibles


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record