Ir al contenido (pulsa Retorno)

Universitat Politècnica de Catalunya

    • Català
    • Castellano
    • English
    • LoginRegisterLog in (no UPC users)
  • mailContact Us
  • world English 
    • Català
    • Castellano
    • English
  • userLogin   
      LoginRegisterLog in (no UPC users)

UPCommons. Global access to UPC knowledge

Banner header
59.728 UPC E-Prints
You are here:
View Item 
  •   DSpace Home
  • E-prints
  • Grups de recerca
  • InSup - Grup de Recerca en Interacció de Superfícies en Bioenginyeria i Ciència dels Materials
  • Articles de revista
  • View Item
  •   DSpace Home
  • E-prints
  • Grups de recerca
  • InSup - Grup de Recerca en Interacció de Superfícies en Bioenginyeria i Ciència dels Materials
  • Articles de revista
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

A robust islanding detection method with zero-non-detection zone for distribution systems with DG

Thumbnail
View/Open
1-s2.0-S0142061521004865-main.pdf (5,944Mb)
Share:
 
 
10.1016/j.ijepes.2021.107247
 
  View Usage Statistics
Cita com:
hdl:2117/360851

Show full item record
Serrano Fontova, AlexandreMés informació
Martínez Velasco, Juan AntonioMés informació
Casals Torrens, PauMés informacióMés informacióMés informació
Bosch Tous, RicardoMés informacióMés informacióMés informació
Document typeArticle
Defense date2021-12-01
Rights accessOpen Access
Attribution-NonCommercial-NoDerivs 4.0 International
Except where otherwise noted, content on this work is licensed under a Creative Commons license : Attribution-NonCommercial-NoDerivs 4.0 International
Abstract
This paper proposes a strategy for detecting unintentional islanding operations (IOs) in distribution networks (DNs) with distributed generation (DG), which eliminating the non-detection zone (NDZ). This hybrid method achieves a zero-NDZ by taking advantage of both passive and active methodologies for an inverter-based DG scenario. The passive-based part of the proposed method considers settings with low thresholds and is activated whenever they are surpassed. The following step uses a three-phase static RC load. This load is connected to intentionally force the frequency and its derivative to exceed the established thresholds. Thus, the events with zero power imbalance can be identified. Unlike other existing methods, this technique does not degrade the power quality (PQ) and does not require DG output power curtailment. The evaluation of the proposed strategy has been carried out through an extensive set of scenarios considering both islanding and non-islanding events. The islanding detection capabilities of the proposed method have been explored considering a custom-made DN test system and the test system recommended by the IEEE 929-2000 standard. The proposed method has a simple implementation, requires a low level of computational complexity, provides a high degree of reliability, and assures fast islanding detection.
CitationSerrano, A. [et al.]. A robust islanding detection method with zero-non-detection zone for distribution systems with DG. "International journal of electrical power and energy systems", 1 Desembre 2021, vol. 133, núm. 107247, p. 107247:1-107247: 16. 
URIhttp://hdl.handle.net/2117/360851
DOI10.1016/j.ijepes.2021.107247
ISSN0142-0615
Publisher versionhttps://www.sciencedirect.com/science/article/pii/S0142061521004865
Collections
  • InSup - Grup de Recerca en Interacció de Superfícies en Bioenginyeria i Ciència dels Materials - Articles de revista [26]
  • Departament d'Enginyeria Elèctrica - Articles de revista [774]
Share:
 
  View Usage Statistics

Show full item record

FilesDescriptionSizeFormatView
1-s2.0-S0142061521004865-main.pdf5,944MbPDFView/Open

Browse

This CollectionBy Issue DateAuthorsOther contributionsTitlesSubjectsThis repositoryCommunities & CollectionsBy Issue DateAuthorsOther contributionsTitlesSubjects

© UPC Obrir en finestra nova . Servei de Biblioteques, Publicacions i Arxius

info.biblioteques@upc.edu

  • About This Repository
  • Contact Us
  • Send Feedback
  • Privacy Settings
  • Inici de la pàgina