Show simple item record

dc.contributor.authorLogothetis, Irini
dc.contributor.authorGil Galí, Ignacio
dc.contributor.authorWang, Xungai
dc.contributor.authorRazal, Joselito
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria Electrònica
dc.date.accessioned2021-11-09T08:33:10Z
dc.date.available2022-04-01T00:36:31Z
dc.date.issued2021-05-01
dc.identifier.citationLogothetis, I. [et al.]. Comparison of silver-plated nylon (Ag/PA66) e-textile and Ag/AgCl electrodes for bioelectrical impedance analysis (BIA). "Biomedical physics and engineering express", 1 Maig 2021, vol. 7, núm. 3, p. 1-27.
dc.identifier.issn2057-1976
dc.identifier.urihttp://hdl.handle.net/2117/355830
dc.description.abstractRecently, researchers have adapted Bioelectrical Impedance Analysis (BIA) as a new approach to objectively monitor wounds. They have indicated various BIA parameters associated to specific wound types can be linked to wound healing through trend analysis relative to time. However, these studies are conducted using wet electrodes which have been identified as possessing several shortcomings, such as unstable measurements. Thus, the adaption of e-textile electrodes has become an area of interest in measuring biosignals. E-textile electrodes are known to possess a significantly large polarization impedance (Zp) that potentially influences these biosignal measurements. In this study we aim to identify the suitability of e-textile electrodes to monitor wounds using BIA methodologies. By adapting suggested methodologies conducted in-vivo from previous studies, we used an ex-vivo model to observe the behaviour of e-textile electrodes relative to time. This was compared to common clinical wet electrodes, specifically Ag/AgCl. The objective of this study was to identify the BIA parameters that can be used to monitor wounds with e-textile electrodes. By analysing the BIA parameters relative to time, we observed the influence of Zp on these parameters.
dc.format.extent27 p.
dc.language.isoeng
dc.publisherInstitute of Physics (IOP)
dc.subject.lcshElectrodes
dc.subject.lcshPolarization (Electricity)
dc.subject.otherElectronic textile electrodes (e-textile electrodes)
dc.subject.otherDry electrodes
dc.subject.otherBioelectrical impedance analysis (BIA)
dc.subject.otherPolarization impedance
dc.subject.otherBiopotential electrodes
dc.subject.otherWearable electrodes
dc.titleComparison of silver-plated nylon (Ag/PA66) e-textile and Ag/AgCl electrodes for bioelectrical impedance analysis (BIA)
dc.typeArticle
dc.subject.lemacElèctrodes
dc.subject.lemacPolarització (Electricitat)
dc.contributor.groupUniversitat Politècnica de Catalunya. RFEMC - Grup de Radiofreqüència i Compatibilitat Electromagnètica en Xarxes de Comunicacions
dc.identifier.doi10.1088/2057-1976/abf2a0
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://iopscience.iop.org/article/10.1088/2057-1976/abf2a0
dc.rights.accessOpen Access
local.identifier.drac32001503
dc.description.versionPostprint (author's final draft)
local.citation.authorLogothetis, I.; Gil, I.; Wang, X.; Razal, J.
local.citation.publicationNameBiomedical physics and engineering express
local.citation.volume7
local.citation.number3
local.citation.startingPage1
local.citation.endingPage27


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

All rights reserved. This work is protected by the corresponding intellectual and industrial property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public communication or transformation of this work are prohibited without permission of the copyright holder