Ir al contenido (pulsa Retorno)

Universitat Politècnica de Catalunya

    • Català
    • Castellano
    • English
    • LoginRegisterLog in (no UPC users)
  • mailContact Us
  • world English 
    • Català
    • Castellano
    • English
  • userLogin   
      LoginRegisterLog in (no UPC users)

UPCommons. Global access to UPC knowledge

Banner header
61.586 UPC E-Prints
You are here:
View Item 
  •   DSpace Home
  • E-prints
  • Programes de doctorat
  • Doctorat en Enginyeria Òptica
  • Ponències/Comunicacions de congressos
  • View Item
  •   DSpace Home
  • E-prints
  • Programes de doctorat
  • Doctorat en Enginyeria Òptica
  • Ponències/Comunicacions de congressos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Residual flatness error correction in three-dimensional imaging confocal microscopes

Thumbnail
View/Open
Residual Flatness Error correction in three dimensional Imaging Confocal Microscopes.pdf (1,493Mb) (Restricted access)   Request copy 

Què és aquest botó?

Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:

  • Disposem del correu electrònic de l'autor
  • El document té una mida inferior a 20 Mb
  • Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
 
10.1117/12.2306903
 
  View Usage Statistics
  LA Referencia / Recolecta stats
Cita com:
hdl:2117/352358

Show full item record
Bermúdez, Carlos
Felgner, André
Martínez Marín, PolMés informació
Matilla Sánchez, Aitor
Cadevall Artigues, CristinaMés informacióMés informacióMés informació
Artigas Pursals, RogerMés informacióMés informacióMés informació
Document typeConference report
Defense date2018
PublisherInternational Society for Photo-Optical Instrumentation Engineers (SPIE)
Rights accessRestricted access - publisher's policy
All rights reserved. This work is protected by the corresponding intellectual and industrial property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
Imaging Confocal Microscopes (ICM) are highly used for the assessment of three-dimensional measurement of technical surfaces. The benefit of an ICM in comparison to an interferometer is the use of high numerical aperture microscope objectives, which allows retrieving signal from high slope regions of a surface. When measuring a flat sample, such as a high-quality mirror, all ICM’s show a complex shape of low frequencies instead of a uniform flat result. Such shape, obtained from a ¿/10, Sa < 0.5 nm calibration mirror is used as a reference for being subtracted from all the measurements, according to ISO 25178-607. This is true and valid only for those surfaces that have small slopes. When measuring surfaces with varying local slopes or tilted with respect to the calibration, the flatness error calibration is no longer valid, leaving what is called the residual flatness error. In this paper we show that the residual flatness error on a reference sphere measured with a 10X can make the measurement of the radius to have up to 10% error. We analyzed the sources that generate this effect and proposed a method to correct it: we measured a tilted mirror with several angles and characterized the flatness error as a function of the distance to the optical axis, and the tilt angle. New measurements take into account such characterization by assessing the local slopes. We tested the method on calibrated reference spheres and proved to provide correct measurements. We also analyzed this behavior in Laser Scan as well on Microdisplay Scan confocal microscopes.
CitationBermúdez, C. [et al.]. Residual flatness error correction in three-dimensional imaging confocal microscopes. A: SPIE Photonics Europe. "Optical Micro- and Nanometrology VII : 25-26 April 2018, Strasbourg, France". Washington: International Society for Photo-Optical Instrumentation Engineers (SPIE), 2018, p. 1106780M:1-1106780M:10. ISBN 9781510618831. DOI 10.1117/12.2306903. 
URIhttp://hdl.handle.net/2117/352358
DOI10.1117/12.2306903
ISBN9781510618831
Publisher versionhttps://www.spiedigitallibrary.org/conference-proceedings-of-spie/10678/106780M/Residual-flatness-error-correction-in-three-dimensional-imaging-confocal-microscopes/10.1117/12.2306903.short?SSO=1
Collections
  • Doctorat en Enginyeria Òptica - Ponències/Comunicacions de congressos [33]
  • GREO - Grup de Recerca en Enginyeria Òptica - Ponències/Comunicacions de congressos [92]
  View Usage Statistics

Show full item record

FilesDescriptionSizeFormatView
Residual Flatne ... g Confocal Microscopes.pdfBlocked1,493MbPDFRestricted access

Browse

This CollectionBy Issue DateAuthorsOther contributionsTitlesSubjectsThis repositoryCommunities & CollectionsBy Issue DateAuthorsOther contributionsTitlesSubjects

© UPC Obrir en finestra nova . Servei de Biblioteques, Publicacions i Arxius

info.biblioteques@upc.edu

  • About This Repository
  • Contact Us
  • Send Feedback
  • Privacy Settings
  • Inici de la pàgina