Mostra el registre d'ítem simple

dc.contributor.authorMartín Navarrete, Rocío
dc.contributor.authorSoria Guerrero, Manel
dc.contributor.authorRodríguez Pérez, Ivette María
dc.contributor.authorLehmkuhl Barba, Oriol
dc.contributor.otherUniversitat Politècnica de Catalunya. Doctorat en Enginyeria Mecànica, Fluids i Aeronàutica
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Física
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament de Màquines i Motors Tèrmics
dc.contributor.otherBarcelona Supercomputing Center
dc.date.accessioned2021-05-17T07:18:50Z
dc.date.available2022-08-07T00:28:43Z
dc.date.issued2021-04-19
dc.identifier.citationMartín, R. [et al.]. On the flow and passive noise control of an open cavity at Re=5000. "Flow turbulence and combustion", 19 Abril 2021, p. 1-27.
dc.identifier.issn1386-6184
dc.identifier.urihttp://hdl.handle.net/2117/345654
dc.description.abstractThe interaction of turbulent flows with the external structure of ground vehicles generates uncomfortable noise and a lot of attention is devoted to find new mechanisms for its suppression. The present work is concerned with open cavity flows, very often found in the automotive industry. A three-dimensional rectangular very wide open cavity with aspect ratio L/D=4 at Reynolds number ReD=5000 and Mach number M=0.1 is considered. The passive control technique is based on eight different geometrical modifications: the length of the cavity, the radius of the trailing, leading and bottom edges and the difference in heights between the left and right wall of the cavity. Wall-resolved Large Eddy Simulations (LES) are used to obtain the flow fields and a post-process based on Curle’s analogy is applied to evaluate the acoustic radiation and the effectiveness of the control mechanisms. The results show that the modifications on the trailing edge are the most effective to control the flow. They allow to reduce the pressure fluctuations produced by the recirculation confined inside the cavity and the abrupt ejection of the flow at the trailing edge. As a consequence, the overall sound pressure level can be decreased up to 9 dB.
dc.format.extent27 p.
dc.language.isoeng
dc.publisherSpringer
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Enginyeria mecànica::Mecànica de fluids
dc.subject.lcshAerodynamics
dc.subject.otherAeroacoustics
dc.subject.otherControl of sound
dc.subject.otherCavity flow
dc.subject.otherLarge Eddy Simulation
dc.subject.otherAcoustic analogy
dc.titleOn the flow and passive noise control of an open cavity at Re=5000
dc.typeArticle
dc.subject.lemacTurbulència -- Mètodes de simulació
dc.subject.lemacAerodinàmica
dc.contributor.groupUniversitat Politècnica de Catalunya. TUAREG - Turbulence and Aerodynamics in Mechanical and Aerospace Engineering Research Group
dc.identifier.doi10.1007/s10494-021-00265-y
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttps://link.springer.com/article/10.1007%2Fs10494-021-00265-y
dc.rights.accessOpen Access
local.identifier.drac31001320
dc.description.versionPostprint (author's final draft)
dc.relation.projectidinfo:eu-repo/grantAgreement/MINECO/1PE/FIS2016-77849-R
local.citation.authorMartín, R.; Soria, M.; Rodriguez, I.; Lehmkuhl , O.
local.citation.publicationNameFlow turbulence and combustion
local.citation.startingPage1
local.citation.endingPage27


Fitxers d'aquest items

Thumbnail

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple