dc.description.abstractA rotating steel cylinder has been heated up to 600ºC in order to be the cooled down seconds later so that desired material properties are obtained or improved. This process is done by the innovative method of multiple water impinging jets. The aim of this project is to develop a better understanding of the advantages of the multiple water impinging jets quenching method and its flexibility to control the cooling rate. The experimental process has been measured and monitored with measurement instruments such as embedded thermocouples, DAQ system and LabVIEW program. In this way, the curve of temperature drop vs time (among others) has been drawn and analyzed. Numerous tests, focused in different parameters of impinging jets setup, have been carried out in order to study the boiling heat transfer and achieve an optimized cooling setup by water impinging jets technique. Jet’s flow rate was varied between 5.6 and 16.7 l/min, as well as cylinder rotation speed (10 - 50 rpm), initial quenching temperature (300 – 600 ºC), jet-to-jet spacing in the jets configuration (S/d = 4 and 6) and the configuration of multiple array of nozzles (staggered and in-line). The results showed that higher cooling rates are obtained by higher jet’s flow rate, but higher temperature difference was also created in material from center to outer point during cooling process. Higher initial temperature resulted in higher cooling rate in onset of quenching. Results revealed that the footprint caused by rotation speed was captured only in very low rotation speed, creating a cyclic oscillation in the temperature history at the beginning of the quenching process. In comparison of multiple arrays, lower cooling rate was obtained in the fountain points between neighbor jets in the in-line array than in the staggered. More uniform cooling rate was found in the footprint of cooling rate in 3-D counter plot in staggered array. Higher cooling rate was achieved with larger jet-to-jet spacing (S/d), but less uniform cooling rate over the area compare to S/d = 4 in staggered pattern.
dc.language.isoeng
dc.publisherUniversitat Politècnica de Catalunya
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Energies
dc.subject.lcshHydraulics--Equipment and instruments
dc.titleQuenching a rotary cylinder by multiple arrays of water impinging jets
dc.typeMaster thesis
dc.subject.lemacHidràulica -- Aparells i instruments
dc.identifier.slugETSEIB-240.149503
dc.rights.accessOpen Access
dc.date.updated2020-11-02T05:38:55Z
dc.audience.educationlevelMàster
dc.audience.mediatorEscola Tècnica Superior d'Enginyeria Industrial de Barcelona
dc.audience.degreeMÀSTER UNIVERSITARI EN ENGINYERIA INDUSTRIAL (Pla 2014)
dc.contributor.covenanteeHögskolan i Gävle


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-ShareAlike 3.0 Spain
Except where otherwise noted, content on this work is licensed under a Creative Commons license : Attribution-NonCommercial-ShareAlike 3.0 Spain