Análisis y estudio del montaje de una instalación frigorífica para refrigeración de máquinas
View/Open
Memòria (6,430Mb) (Restricted access)
Article (1,189Mb) (Restricted access)
Cita com:
hdl:2117/329203
CovenanteeIngetermia Engineering
Document typeBachelor thesis
Date2020-07-02
Rights accessRestricted access - author's decision
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
[CASTELLÀ] Este proyecto consiste en el análisis y diseño del montaje de una instalación frigorífica para refrigeración de máquinas, y su correspondiente oferta económica, desde el momento de su encargo a una empresa de ingeniería especializada en instalaciones de climatización y refrigeración industrial, hasta su ejecución final. Después de un breve repaso histórico del progreso de los sistemas de refrigeración, y de sus fundamentos, se describen los diferentes elementos que componen una instalación de refrigeración. El capítulo cuatro, se centrará en los principales sistemas de enfriamiento respetuosos con el medio ambiente que existen en la actualidad a nivel industrial, como son las torres de refrigeración y las aeroenfriadoras adiabáticas para seleccionar el más adecuado a los requerimientos de nuestro proyecto desde un punto de vista técnico-económico. Para realizar este comparativo se han utilizado varios programas informáticos con los que se han ido haciendo diferentes simulaciones hasta cumplir con las necesidades de nuestro proyecto. Para las torres de refrigeración se ha utilizado el software Selección SimCT, facilitado por la empresa JNegre, distribuidora de las torres de refrigeración EWK, y para las aeroenfriadoras adiabáticas, se ha utilizado en software UNILAB UNIT V. 6 facilitado por la empresa Intersam, fabricante a su vez de aeroenfriadoras adiabáticas. De este comparativo se deduce que el sistema más adecuado para el requerimiento del proyecto es el que utiliza aeroenfriadoras adiabáticas. Posteriormente, se ha utilizado el programa de cálculo que la empresa Grundfos, fabricante de bombas hidráulicas dispone en su página web, y se han calculado las bombas necesarias para los circuitos de acuerdo con las pérdidas de carga de la instalación. Así mismo, con ayuda del programa de cálculo de intercambiadores de placas que la empresa Suicalsa ha facilitado se ha calculado el intercambiador que se necesitaba para reforzar la línea de producción existente. Una vez definidos todos los equipos importantes del sistema de refrigeración, a partir del diseño del esquema hidráulico de la instalación se ha procedido a confeccionar el estado de mediciones y presupuesto de la instalación que ha incluido tanto el coste del material como el de la mano de obra, para finalmente llevarla a cabo. [ANGLÈS] This Project consists on the analysis and design of the assembly of a refrigerated installation to refrigerate process machines and its related economic offer, since the moment of its order to an engineer company specialized on air conditioning and industrial refrigeration, to its final execution. After a short historic review of the progress of the refrigeration systems, and its fundamentals, are described the different elements that compounds a refrigerant installation. The fourth chapter, will focus on the main environmentally friendly cooling systems that currently exist at an industrial level, such as cooling towers adiabatic air coolers to select the most suitable one for the requirements of our project from one point from a technical-economic point of view. In order to carry out this comparison, various computer programs have been used with which different simulations have been carried out to meet the needs of our project. For the cooling towers, the Selección SimCT software provided by the company JNegre, distributor of the EWK cooling towers, has been used, and for the adiabatic drycoolers, it has been used in UNILAB UNIT V.6 software provided by the company Intersam, also manufacturer on adiabatic dry coolers. From this comparison it follows that the most suitable system for the project requirement is the one that uses adiabatic dry coolers. Subsequently, the calculation program that the Company Grundfos, manufacturer of hydraulic pumps has on its website, has been used, and the necessary pumps for the circuits have been calculated according to the installation’s head losses. Likewise, with the help of the plate heat exchanger calculation program that the company Suicalsa has provided, the heat exchanger that was needed to reinforce the existing production line has been calculated. Once all the important equipment of the refrigeration system has been defined, from the design of the hydraulic diagram of the installation, the measurement status and the budget of the installation have been prepared, which has included both the cost of the material and the cost of work, to finally be able to carry it out.
DegreeGRAU EN ENGINYERIA MECÀNICA (Pla 2009)
Files | Description | Size | Format | View |
---|---|---|---|---|
TFG_Pere_Martin ... nstalación_frigorifica.pdf | Memòria | 6,430Mb | Restricted access | |
Articulo_TFG_Pere_Martinez_Ibar.pdf | Article | 1,189Mb | Restricted access |