An interpolation method to calibrate electromagnetic probes in semi-anechoic chambers

Thumbnail
View/Open
AN INTERPOLATION METHOD TO CALIBRATE ELECTROMAGNETIC PROBES IN SEMIANECHOIC CHAMBERS.pdf (285,7Kb) (Restricted access)   Request copy 

Què és aquest botó?

Aquest botó permet demanar una còpia d'un document restringit a l'autor. Es mostra quan:

  • Disposem del correu electrònic de l'autor
  • El document té una mida inferior a 20 Mb
  • Es tracta d'un document d'accés restringit per decisió de l'autor o d'un document d'accés restringit per política de l'editorial
 
10.2528/PIERB12012604
 
  View UPCommons Usage Statistics
  LA Referencia / Recolecta stats
Includes usage data since 2022
Cita com:
hdl:2117/28162

Show full item record
Tremola, Ciro
Azpúrua Auyanet, Marco AurelioMés informacióMés informacióMés informació
Páez, Eduardo Javier
Ormeño, D.
Rebolledo, A.
Document typeArticle
Defense date2012
Rights accessRestricted access - publisher's policy
Attribution-NonCommercial-NoDerivs 3.0 Spain
This work is protected by the corresponding intellectual and industrial property rights. Except where otherwise noted, its contents are licensed under a Creative Commons license : Attribution-NonCommercial-NoDerivs 3.0 Spain
Abstract
Based upon the standard IEEE 1309, a new calibration method for electromagnetic (EM) probes is proposed. The aforementioned method compares the electric field strength measured with the EM probe subject to calibration with the E-field intensity calculated through a linear interpolation of the corrected measurement using a reference EM probe. The corrected measurement results are computed by means of the calibration factors stated in the calibration certificate of the reference EM probe. The conditions and criteria, under which it is possible to calibrate EM probes inside semi-anechoic chambers in the frequency range of 80 MHz to 1 GHz, are presented. The results shows that the calibration method proposed in this paper is characterized by deviations less than 1 dB in almost all the frequencies considered, verifying the reliability of the method. The proposed approach is very useful for registering the measurement drift of EM probes used in EMC testing laboratories
CitationTremola, C. [et al.]. An interpolation method to calibrate electromagnetic probes in semi-anechoic chambers. "Progress in electromagnetics research B", 2012, vol. 39, p. 355-371. 
URIhttp://hdl.handle.net/2117/28162
DOI10.2528/PIERB12012604
ISSN1937-6472
Publisher versionhttp://www.jpier.org/PIERB/pier.php?paper=12012604
Collections
      View UPCommons Usage Statistics

    Show full item record

    FilesDescriptionSizeFormatView
    AN INTERPOLATIO ... SEMIANECHOIC CHAMBERS.pdfBlocked285,7KbPDFRestricted access

    Browse

    This CollectionBy Issue DateAuthorsOther contributionsTitlesSubjectsThis repositoryCommunities & CollectionsBy Issue DateAuthorsOther contributionsTitlesSubjects

    © UPC Obrir en finestra nova . Servei de Biblioteques, Publicacions i Arxius

    info.biblioteques@upc.edu

    • About This Repository
    • Metadata under:Metadata under CC0
    • Contact Us
    • Send Feedback
    • Privacy Settings
    • Inici de la pàgina