Mostra el registre d'ítem simple

dc.contributor.authorLiao, Lin
dc.contributor.authorPialarissi Cavalaro, Sergio Henrique
dc.contributor.authorFuente Antequera, Albert de la
dc.contributor.authorAguado de Cea, Antonio
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de la Construcció
dc.date.accessioned2015-05-20T18:05:23Z
dc.date.created2014
dc.date.issued2014
dc.identifier.citationLiao, L. [et al.]. Complementary use of inductive test and bending test for the characterization of SFRC. A: International Conference on Civil Engineering. "4th International Conference on Civil Engineering". Haikou: 2014, p. 2213-2219.
dc.identifier.urihttp://hdl.handle.net/2117/27994
dc.description.abstractMany researches have been conducted in past decades for promoting the application of steel fibre reinforced concrete (SFRC), either conventional or self-compacting. However, the differences of post-crack behaviour and the properties of these two types of concrete remains unclear. The objective of this paper is to analyse such differences in terms of flexural behaviour, fibre orientation and contribution as well as the fibre content. For that, an extensive experimental campaign was carried out. In total 3 mixes of self-compacting and 3 mixes with traditional concrete were produced with the nominal fibre contents of 30kg/m3, 45kg/m3 and 60kg/m3. In each series, specimens were produces and characterized by three point bending test (code EN 14651) and inductive test. The results illustrate how fibre orientation and distribution justify the differences in the mechanical behaviour of the materials and the scatter of the bending test results.
dc.format.extent7 p.
dc.language.isoeng
dc.subjectÀrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó
dc.subject.lcshFiber-reinforced concrete--Testing
dc.subject.lcshSteel fibers
dc.subject.otherCSFRC
dc.subject.otherSFRSCC
dc.subject.otherBending test
dc.subject.otherInductive test
dc.subject.otherFibre orientation
dc.subject.otherFibre distribution
dc.titleComplementary use of inductive test and bending test for the characterization of SFRC
dc.typeConference lecture
dc.subject.lemacConstrucció en formigó armat amb fibres d'acer
dc.contributor.groupUniversitat Politècnica de Catalunya. EC - Enginyeria de la Construcció
dc.identifier.doi10.4028/www.scientific.net/AMM.580-583.2213
dc.relation.publisherversionhttp://www.scientific.net/AMM.580-583.2213
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac15591554
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorLiao, L.; Pialarissi Cavalaro, S.H.; de la Fuente, A.; Aguado, A.
local.citation.contributorInternational Conference on Civil Engineering
local.citation.pubplaceHaikou
local.citation.publicationName4th International Conference on Civil Engineering
local.citation.startingPage2213
local.citation.endingPage2219


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple