Cancellation of cardiac interference in diaphragm EMG signals using an estimate of ECG reference signal

Cita com:
hdl:2117/27250
Document typeConference report
Defense date2014
Rights accessOpen Access
All rights reserved. This work is protected by the corresponding intellectual and industrial
property rights. Without prejudice to any existing legal exemptions, reproduction, distribution, public
communication or transformation of this work are prohibited without permission of the copyright holder
Abstract
The analysis of the electromyographic signal of the diaphragm muscle (EMGdi) can provide important information in order to evaluate the respiratory muscular function. However, EMGdi signals are usually contaminated by the electrocardiographic (ECG) signal. An adaptive noise cancellation (ANC) based on event-synchronous cancellation can be used to reduce the ECG interference in the recorded EMGdi activity. In this paper, it is proposed an ANC scheme for cancelling the ECG interference in EMGdi signals using only the EMGdi signal (without acquiring the ECG signal). In this case the detection of the QRS complex has been performed directly in the EMGdi signal, and the ANC algorithm must be robust to false or missing QRS detections. Furthermore, an automatic criterion to select the adaptive constant of the LMS algorithm has been proposed (µ). The µ constant is selected automatically so that the canceling signal energy equals the energy of the reference signal (which is an estimation of the ECG interference present in the EMGdi signal). This approach optimizes the tradeoff between cancellation of ECG interference and attenuation of EMG component. A number of weights equivalent of a time window that contains several QRS complexes is selected in order to make the algorithm robust to QRS detection errors.
CitationTorres, A.; Fiz, J.; Jane, R. Cancellation of cardiac interference in diaphragm EMG signals using an estimate of ECG reference signal. A: "IFMBE Proceedings : XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013 : MEDICON 2013, 25-28 September 2013, Seville, Spain". 2014, p. 1000-1004.
ISBN978-3-319-00845-5
Publisher versionhttp://link.springer.com/chapter/10.1007/978-3-319-00846-2_248
Collections
- Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial - Ponències/Comunicacions de congressos [1.438]
- BIOSPIN - Biomedical Signal Processing and Interpretation - Ponències/Comunicacions de congressos [70]
- IBEC - Institute for Bioengineering of Catalonia - Ponències/Comunicacions de congressos [75]
Files | Description | Size | Format | View |
---|---|---|---|---|
Cancellation_of ... f_ECG_Reference_Signal.pdf | 280,4Kb | View/Open |