Mostra el registre d'ítem simple

dc.contributor.authorBlesa Izquierdo, Joaquim
dc.contributor.authorJiménez, Pedro
dc.contributor.authorRotondo, Damiano
dc.contributor.authorNejjari Akhi-Elarab, Fatiha
dc.contributor.authorPuig Cayuela, Vicenç
dc.contributor.otherUniversitat Politècnica de Catalunya. Departament d'Enginyeria de Sistemes, Automàtica i Informàtica Industrial
dc.date.accessioned2015-02-26T13:31:48Z
dc.date.created2014-12-25
dc.date.issued2014-12-25
dc.identifier.citationBlesa, J. [et al.]. An interval NLPV parity equations approach for fault detection and isolation of a wind farm. "IEEE transactions on industrial electronics", 25 Desembre 2014, vol. PP, núm. 99, p. 1-11.
dc.identifier.issn0278-0046
dc.identifier.urihttp://hdl.handle.net/2117/26522
dc.description.abstractIn this paper, the problem of fault diagnosis of a wind farm is addressed using interval nonlinear parameter varying (NLPV) parity equations. Fault detection is based on the use of parity equations assuming unknown but bounded description of the noise and modeling errors. The fault detection test is based on checking the consistency between the measurements and the model by finding if the formers are inside the interval prediction bounds. The fault isolation algorithm is based on analyzing the observed fault signatures on-line, and matching them with the theoretical ones obtained using structural analysis. Finally, the proposed approach is tested using the wind farm benchmark proposed in the context of the wind farm FDI/FTC competition.
dc.format.extent11 p.
dc.language.isoeng
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)
dc.subjectÀrees temàtiques de la UPC::Informàtica::Automàtica i control
dc.subject.lcshWind power plants
dc.subject.lcshAutomatic control
dc.subject.lcshUncertainty
dc.subject.lcshEquations
dc.subject.lcshTurbines
dc.subject.otherFault diagnosis
dc.subject.otherWind farm
dc.subject.otherInterval NLPV parity equations
dc.titleAn interval NLPV parity equations approach for fault detection and isolation of a wind farm
dc.typeArticle
dc.subject.lemacParcs eòlics
dc.subject.lemacControl automàtic
dc.subject.lemacEquacions
dc.subject.lemacIncertesa
dc.subject.lemacTurbines
dc.contributor.groupUniversitat Politècnica de Catalunya. SIC - Sistemes Intel·ligents de Control
dc.contributor.groupUniversitat Politècnica de Catalunya. SAC - Sistemes Avançats de Control
dc.identifier.doi10.1109/TIE.2014.2386293
dc.description.peerreviewedPeer Reviewed
dc.relation.publisherversionhttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?reload=true&arnumber=6998858&sortType%3Dasc_p_Sequence%26filter%3DAND%28p_Publication_Number%3A41%29%26pageNumber%3D6%26rowsPerPage%3D50
dc.rights.accessOpen Access
local.identifier.drac15436506
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorBlesa, J.; Jiménez, P.; Rotondo, D.; Nejjari, F.; Puig, V.
local.citation.publicationNameIEEE transactions on industrial electronics
local.citation.volumePP
local.citation.number99
local.citation.startingPage1
local.citation.endingPage11