Mostra el registre d'ítem simple

dc.contributor.authorCarinou, Eleftheria
dc.contributor.authorGinjaume Egido, Mercè
dc.contributor.authorO'Connor, Una
dc.contributor.authorKopec, Renata
dc.contributor.authorSans Merce, Marta
dc.contributor.otherUniversitat Politècnica de Catalunya. Institut de Tècniques Energètiques
dc.date.accessioned2015-02-18T12:35:00Z
dc.date.created2014-12-01
dc.date.issued2014-12-01
dc.identifier.citationCarinou, E. [et al.]. Status of eye lens radiation dose monitoring in European hospitals. "Journal of radiological protection", 01 Desembre 2014, vol. 34, núm. 4, p. 729-739.
dc.identifier.issn0952-4746
dc.identifier.urihttp://hdl.handle.net/2117/26410
dc.description.abstractA questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.
dc.format.extent11 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Ciències de la salut::Medicina::Oftalmologia
dc.subjectÀrees temàtiques de la UPC::Física::Electromagnetisme::Radiació infraroja, visible i ultraviolada
dc.subject.lcshRadiology
dc.subject.otherQuestionnaire
dc.subject.otherEye lens limit
dc.subject.otherEye lens dosemeters
dc.subject.otherRadiation protection
dc.titleStatus of eye lens radiation dose monitoring in European hospitals
dc.typeArticle
dc.subject.lemacRadiologia
dc.contributor.groupUniversitat Politècnica de Catalunya. GREENER - Grup de recerca d'estudis energètics i de les radiacions
dc.identifier.doi10.1088/0952-4746/34/4/729
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac15371074
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorCarinou, E.; Ginjaume, M.; O'Connor, U.; Kopec, R.; Sans, M.
local.citation.publicationNameJournal of radiological protection
local.citation.volume34
local.citation.number4
local.citation.startingPage729
local.citation.endingPage739


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple