dc.contributor.author | Zhang, Weiyi |
dc.contributor.author | Mir Cantarellas, Antonio |
dc.contributor.author | Remón, D. |
dc.contributor.author | Luna Alloza, Álvaro |
dc.contributor.author | Rodríguez Cortés, Pedro |
dc.contributor.other | Universitat Politècnica de Catalunya. Departament d'Enginyeria Elèctrica |
dc.date.accessioned | 2015-02-11T11:43:04Z |
dc.date.created | 2014 |
dc.date.issued | 2014 |
dc.identifier.citation | Zhang, W. [et al.]. A proportional resonant controller tuning method for grid connected power converters with LCL+trap filter. A: IEEE International Conference on Renewable Energy Research and Applications. "Proceedings ICRERA 2014". Milwakuee: 2014, p. 445-450. |
dc.identifier.uri | http://hdl.handle.net/2117/26299 |
dc.description.abstract | Three-phase power converters are largely employed in power generation facilities based on renewable energy sources, and these converters commonly working in grid connection mode are frequently connected to the grid through passive filters. Nowadays the need for larger power converter-based generation plants increases continuously, and LCL+trap filter arises as a solution when switching frequency is reduced due to the power increase. However, the tuning of current controllers becomes more complex as the LCL+trap filter lead to a considerably high order system. In this work a method for tuning the gains of proportional resonant current controllers for three-phase high power converters linked to the grid through a LCL+trap filter is proposed and analyzed. Simulation and experimental results taken in different cases are shown to validate the proposed method. |
dc.format.extent | 6 p. |
dc.language.iso | eng |
dc.subject | Àrees temàtiques de la UPC::Energies::Energia elèctrica::Automatització i control de l’energia elèctrica |
dc.subject.lcsh | Electric power distribution |
dc.subject.lcsh | Electric current converters |
dc.subject.lcsh | Electric circuits--Direct current |
dc.subject.lcsh | Electric circuits--Alternating current |
dc.subject.other | DC-AC power converters |
dc.subject.other | Distributed power generation |
dc.subject.other | Automatic control |
dc.subject.other | Closed loop systems |
dc.subject.other | Control design |
dc.title | A proportional resonant controller tuning method for grid connected power converters with LCL+trap filter |
dc.type | Conference report |
dc.subject.lemac | Sistemes de distribució d'energia elèctrica |
dc.subject.lemac | Convertidors altern-continu |
dc.contributor.group | Universitat Politècnica de Catalunya. SEER - Sistemes Elèctrics d'Energia Renovable |
dc.identifier.doi | 10.1109/ICRERA.2014.7016425 |
dc.description.peerreviewed | Peer Reviewed |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 15428853 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Zhang, W.; Cantarellas, A.M.; Remón, D.; Luna, A.; Rodriguez, P. |
local.citation.contributor | IEEE International Conference on Renewable Energy Research and Applications |
local.citation.pubplace | Milwakuee |
local.citation.publicationName | Proceedings ICRERA 2014 |
local.citation.startingPage | 445 |
local.citation.endingPage | 450 |