Mostra el registre d'ítem simple
Ambient dose estimationH*(10) from LaBr3(Ce) spectra
dc.contributor.author | Camp Brunés, Anna |
dc.contributor.author | Vargas Drechsler, Arturo |
dc.contributor.other | Universitat Politècnica de Catalunya. Institut de Tècniques Energètiques |
dc.date.accessioned | 2014-11-11T12:20:49Z |
dc.date.created | 2014-08-01 |
dc.date.issued | 2014-08-01 |
dc.identifier.citation | Camp, A.; Vargas, A. Ambient dose estimationH*(10) from LaBr3(Ce) spectra. "Radiation protection dosimetry", 01 Agost 2014, vol. 160, núm. 4, p. 264-268. |
dc.identifier.issn | 0144-8420 |
dc.identifier.uri | http://hdl.handle.net/2117/24677 |
dc.description.abstract | The stripping method for ambient dose estimation has been used for detectors such as high-purity Ge (HPGe). This method strips the spectrum from the partial absorptions produced in the detector leaving only the events corresponding to the full absorption of a gamma ray. In the present study, this method is applied to a 1 '' x 1 '' LaBr3(Ce) detector using the PENELOPE/penEasy Monte Carlo code to obtain both the partial absorptions and detector full peak efficiency. The stripping method has been validated from a set of gamma fluxes carried out at the accredited laboratory of the Institute of Energy Technologies of the Technical University of Catalonia and results were obtained with differences <5 %. After validation, the LaBr3(Ce) monitor was installed on the roof of the institute premises working in parallel with a photon equivalent dose monitor, model FHZ 601A from the FAG Company. The derived H*(10) values from the LaBr3(Ce) detector show good agreement with those derived from the dose monitor. |
dc.format.extent | 5 p. |
dc.language.iso | eng |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 Spain |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
dc.subject | Àrees temàtiques de la UPC::Energies |
dc.subject | Àrees temàtiques de la UPC::Desenvolupament humà i sostenible::Medi ambient |
dc.subject.lcsh | Environmental degradation |
dc.title | Ambient dose estimationH*(10) from LaBr3(Ce) spectra |
dc.type | Article |
dc.subject.lemac | Medi ambient--Degradació |
dc.contributor.group | Universitat Politècnica de Catalunya. GREENER - Grup de recerca d'estudis energètics i de les radiacions |
dc.identifier.doi | 10.1093/rpd/nct342 |
dc.relation.publisherversion | http://rpd.oxfordjournals.org/content/160/4/264.full.pdf |
dc.rights.access | Restricted access - publisher's policy |
local.identifier.drac | 15177815 |
dc.description.version | Postprint (published version) |
dc.date.lift | 10000-01-01 |
local.citation.author | Camp, A.; Vargas, A. |
local.citation.publicationName | Radiation protection dosimetry |
local.citation.volume | 160 |
local.citation.number | 4 |
local.citation.startingPage | 264 |
local.citation.endingPage | 268 |
Fitxers d'aquest items
Aquest ítem apareix a les col·leccions següents
-
Articles de revista [178]
-
Articles de revista [285]