dc.identifier.citationCamp, A.; Vargas, A. Ambient dose estimationH*(10) from LaBr3(Ce) spectra. "Radiation protection dosimetry", 01 Agost 2014, vol. 160, núm. 4, p. 264-268.
dc.identifier.issn0144-8420
dc.identifier.urihttp://hdl.handle.net/2117/24677
dc.description.abstractThe stripping method for ambient dose estimation has been used for detectors such as high-purity Ge (HPGe). This method strips the spectrum from the partial absorptions produced in the detector leaving only the events corresponding to the full absorption of a gamma ray. In the present study, this method is applied to a 1 '' x 1 '' LaBr3(Ce) detector using the PENELOPE/penEasy Monte Carlo code to obtain both the partial absorptions and detector full peak efficiency. The stripping method has been validated from a set of gamma fluxes carried out at the accredited laboratory of the Institute of Energy Technologies of the Technical University of Catalonia and results were obtained with differences <5 %. After validation, the LaBr3(Ce) monitor was installed on the roof of the institute premises working in parallel with a photon equivalent dose monitor, model FHZ 601A from the FAG Company. The derived H*(10) values from the LaBr3(Ce) detector show good agreement with those derived from the dose monitor.
dc.format.extent5 p.
dc.language.isoeng
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subjectÀrees temàtiques de la UPC::Energies
dc.subjectÀrees temàtiques de la UPC::Desenvolupament humà i sostenible::Medi ambient
dc.subject.lcshEnvironmental degradation
dc.titleAmbient dose estimationH*(10) from LaBr3(Ce) spectra
dc.typeArticle
dc.subject.lemacMedi ambient--Degradació
dc.contributor.groupUniversitat Politècnica de Catalunya. GREENER - Grup de recerca d'estudis energètics i de les radiacions
dc.identifier.doi10.1093/rpd/nct342
dc.relation.publisherversionhttp://rpd.oxfordjournals.org/content/160/4/264.full.pdf
dc.rights.accessRestricted access - publisher's policy
local.identifier.drac15177815
dc.description.versionPostprint (published version)
dc.date.lift10000-01-01
local.citation.authorCamp, A.; Vargas, A.
local.citation.publicationNameRadiation protection dosimetry
local.citation.volume160
local.citation.number4
local.citation.startingPage264
local.citation.endingPage268


Fitxers d'aquest items

Imatge en miniatura

Aquest ítem apareix a les col·leccions següents

Mostra el registre d'ítem simple